,QLWLDO6HWXS
 Feed Line From Carbon Filter
to Membranes
 Puried Water Lines (Blue)

Waste Water Lines (Black)

Automatic Shut-o Valve

Flow Restrictor
Connect the 1/4” blue purified water tubing to the outlet of the Automatic
Shut-o valve. The system comes with a 3:1 waste water to puried water
ratio. This is industry standard for most water sources and gives you
the best trade o between membrane life and waste water. If you have
relatively low PPM source water or need a more ecient ratio you can choose
to use the optional 2:1 Eco-Waste Reducer included with your system.
(see instructions on Eco-Waste Reducer) or purchase the 1:1
ow restrictor
+/ (call your dealer or Hydro-Logic).
Refer to specications on these two options for detailed info on their
applications.
Connect the 1/4” black waste water tubing to the outlet of the flow
restrictor. You are now ready to connect the included garden hose adaptor
to your source water and the other end of the 3/8” white inlet tubing.
There are a variety of feed valve options available to connect to any existing
plumbing. Inquire at your dealer, or through Hydro-Logic.
Push in the 3/8" white inlet tubing into the 3/8” QC pressure gauge tting.
VWHDOWK52