Manual

4
370 Encinal Street, Suite 150
Santa Cruz, Ca 95060
P: 888-426-5644 / F: 831-336-9840
www.hydrologicsystems.com
This system has been designed for installa on by a licensed professional such as a contractor or plumber. Proper comple on of this
installa on will require basic familiarity with standard sink plumbing and proper use of common hand and power tools. Improperly
installed systems could result in water damage due to leaks or ooding. Do not use with water that is microbiologically unsafe.
System Speci ca ons
Membrane System w/Tank
Pressure 40-80 psi (275 kPa - 552 kPa)
Temp 40°F - 100°F (4°C - 38°C)
TDS <2000 mg/L
Chlorine <1.0 mg/L
Turbidity <1 NTU
SDI <5
pH 4-8
Performance Speci ca ons
Feed water must be potable, municipal water. Must
be free of poten al membrane foulants such as Iron,
Hydrogen Sul de and Manganese.
Produc on 40 GPD 21.6 GPD
(151 LPD) (81.8 LPD)
TDS Rejec on 95% 95%
Recovery
1
26.3% 17%
Brine to Product 2.8:1 4.86:1
1
The percentage of the feed water available as reverse osmosis treated
water under normal opera ng condi ons.
Tested at 60 psig (4 bar), 500ppm TDS municipal water, 77°F (25°C)
Feed Water Requirements
System - 9.72” W x 13.75” D x 15.38” H ( 24.7 x 34.9 x 39.1 cm), 11 lbs. (5 kg.)
Shipping Box - 14.5"L x 11.25"W x 20"H (36.8 x 28.6 x 50.8 cm), 13.7 lbs. (6.2 kg.)
Dimensions and Weight
A. Product water storage tank
B. Tank valve
C. Tank tubing (3/8” white)
D. Air-gap faucet
E. Drain connec on assembly
F. Drain tubing (3/8” white)
G. Quick connect ng
H. Drain tubing (1/4” black)
I. Faucet tubing (3/8” blue)
J. Four-stage desalinator cartridge
K. Feed water tubing (1/4” green)
L. Inlet ng with shut-o
M. GAC and remineraliza on post- lter
A
B
J )
E
F
G
D
K
L
M
I
H
C (not shown)