Warranty

Always disconnect the xture from the mains before performing any task on it.
Always allow for a cool down period of at least 30 minutes before touching the lamp or reector. Touching the
lamp or the reector when the lamp is lit or immediately a
erwards will result in severe burns!
Do not use the xture near ammable, explosive or reac
ve substances. The lamp and the reector of the
xture become very hot during use.
Do not use sulfur vaporizers or water misters close to your xture. Sulfur and calcium deposits on your reector
will decrease its eciency.
Never touch the lamp or the inside of the reector with bare hands as this will cause damage to the lamp or
reector.
6. Installing the Fixture
Warning! Avoid coiled cords. Coiled cords may lead
to electromagne c interference.
Warning! Always install the lamp bef
ore connec
ng the xture to the mains.
Warning! Ensure the local cabling can support the voltage and current requirements of the xture.
6.1. Adjus
ng the Output of the Lamp Manually
Note: Adjustment occurs gradually (60 seconds per step) to increase the lifespan of the lamp.
Install the lamp in the xture
Turn the output control knob to adjust the output of the lamp: 600/750/1000/1150 Wa
7. Fixture Use
Warning! Never use the xtu
re without a lamp or reector!
8. Inspec
on, Maintenance and Repair
Warning! Disconnect the xture from mains before performing any maintenance or repairs.
Warning! Do not open or disassemble the xture, it contains no serviceable parts inside. Opening the xture can be
dangerous and will void the warranty.
Warning! Always allow for a cool down period of at least 30 minutes before touching the lamp or reector.
Cau
on! Do not clean the xture with detergents, abrasives or other aggressive substances.
Cau
on! Do not touch the inside of the reector and do not use water, abrasives or detergents to clean it. This will
damage the reec ve surface.
Cau
on! Wait 20 minutes before ac va ng the xture a er maintenance work has been conducted.
Regularly check the xture for dust or dirt buildup. Clean if necessary.
Contamina
on may cause overhea
ng and decreased performance.
Clean the inside of the reector only with a so
, dry cloth.
Clean the electric ballast and the outside of the xture using a dry or damp cloth.
Check the lamp monthly for discolora
ons or black markings. Always replace a damaged lamp.
Regularly check the wiring of the xture to ensure it is undamaged.
4
8.1. Placement and Replacement of the Lamp
Cau
on! Do not touch the lamp with bare hands as this will damage the lamp.
Always use a fabric glove to handle the lamp.
Note: The lamp must be replaced every year or a
er 5000 ligh ng hours, whichever one comes rst.
Hold the lamp with a fabric glove to prevent it from falling. Use a protec
ve glove if the lamp is damaged.
Open the cap of lamp holders (A).
Carefully take the lamp out.
Straightening the wires of the lamp (B).
Install the new lamp
(C).
Use a fabric glove to carefully press the lamp in the
ng un the springs hold the lamp.
Close the cap of the lamp holders, make sure the cap of lamp holders are closed htly (D).
Plug the xture back into the mains.
8.2. Placement and Replacement of the Reector
Note: You have to remove the lamp to replace the reector.
Depending on the environment and contamina
on levels the reector will degrade.
Loosen the two screws on the top of the bracket.
Remove the reector.
Place the new reector,
ghten the screws.
5