- 2. INSTALLATION
- 2.2 Secure AMHM to Mounting Accessory
- 2.3 Secure AMHM to Mounting Accessory
Installation Guide 4
AMHM
Installation Manual
NOTE: HYDREL RESERVES THE RIGHT TO MODIFY SPECIFICATION WITHOUT NOTICE.
Any dimension on this sheet is to be assumed as a reference dimension:
“Used for information purposes only. It does not govern manufacturing or inspection requirements.” (ANSI Y14.5-1973)
Model AMHM | 11/01/21 | REV -
©2019 Hydrel Rev. | One Lithonia Way, Conyers, GA 30012
Phone: 1800.705.SERV (7378) | www.hydrel.com
2. INSTALLATION
Model AMHM may be mounted directly onto a mounting
accessory of choice.
HYDREL recommends the following mounting accessory
models: ADPMR/ADPMS, AMPC, APAR/APAS,
AWSC, CAJB, CJB, CPM, CPMSA, CSM and CWMAE/
CWMAT
2.1 Secure Luminaire(s) to the AMHM
1. Open the AMHM’s splice compartment by removing
the AMHM Cover.
2. Position the Luminaire in desired AMHM location
(Note: The AMHM can accommodate a maximum of
4 Luminaires).
3. Ensure the Luminaire Gasket is placed between the
Luminaire and the AMHM.
4. Rotate the Luminaire to desired position.
1. Secure the Luminaire to the AMHM using the included
Backup Nut (Torque to 30 in-lb).
2. Make needed electrical connections.
3. If adding more Luminaires to the AMHM, repeat steps
2 through 6.
4. Close the AMHM’s splice compartment by securing
the AMHM Cover using the provided fasteners