Installation Manual Instruction Manual

Installation Manual
© Hydra-Flex Inc 2011
- 7 -
Pump Assembly need to be within 6’ of furthest Aqua-Lab
panel
1. Drill 3/8” holes in wall for bottom slots (20” on center pump
nose down, 3.5” on center pump nose sidewise Dual
stand)
2. Insert concrete anchors, set pump on bolts and tighten
down.
3. Hold pump stand in place, drill top holes, insert anchors
and tighten
Motor Starter
o Mount to the wall with 4 appropriate anchors
Use these slots if mounting
pump nose down