Manual

GSM Radio Module CSI-F-10 Page 111
Status 29.01.2009 HYDAC ELECTRONIC GMBH Part.-Nr.: 669752
10.1 Overriding Error Messages
10.1.1 Function not Available in this Mode
The CM program has been compiled for a platform in which the marked function does
not exist.
Check the platform setting and correct it or modify the CM program accordingly.
10.2 Error Messages with Data Sources
10.2.1 Invalid Channel Setting
A channel/subchannel has been selected that is not valid.
Check the channel setting and correct it.
10.2.2 Duplicate Channel Name
The name of a channel may only be used once in a CM program.
Check the channel name and correct it.
10.2.3 Invalid Digital Input
A port must be set for the digital input function.
Check the port setting and correct it.
10.2.4 Duplicate Digital Input
A port must be set for the digital input function. This set port may only be used once
in a CM program.
Check the port setting and correct it.
10.2.5 Too many Boolean Input Fields
A maximum of 50 Boolean input values are permitted to be present in a single CM
program.
Reduce the Boolean input values to a maximum of 50.
10.2.6 No Inscription for Boolean Input
The Boolean input value must have an inscription.
Enter an inscription in the function properties.
10.2.7 Duplicate Inscription for Boolean Inputs
The inscription of a Boolean input value must be unambiguous within a CM program
and is only permitted to occur once for that reason.
Check the inscription and correct it.
10.2.8 Too Many Numerical Input Values
A maximum of 50 numerical input values are permitted to be present in a single CM
program.
Reduce the numerical input values to a maximum of 50.