User guide
ContaminationSensor CS1000 Technical data
HYDAC Filtertechnik GmbH
en
Page 94 / 100
BeWa CS1000 3247149n en 2009-02-04.doc 2009-02-04
Technical data
General data
Mounting position Any (recommended: vertical position)
Self-diagnosis Continuously with error display
via status LED and display
Display (only CS 1x2x) LED, 6 digits, in 17 segment format
Measurement categories CS 12xx ISO / SAE
CS 13xx ISO / SAE / NAS
Service categories Flow (ml/min)
Out (mA) or (VDC), according to model
Drive (%)
Temp (°C) and (°F)
Ambient temperature range
-30° ... +80° C / -22° ... 176° F
Storage temperature range
-40° ... +80° C / -40° ... 176° F
Relative humidity
Max. 95%, non-condensing
Sealing material
CS 1xx0 = FPM
CS 1xx1 = EPDM
Protection class
III (low voltage protection)
Protection system
IP67
Weight
1.3 kg
Electrical data
Connection plug M12x1, 8 pole, specified in DIN VDE 0627
Power supply voltage 9 – 36 V DC, residual ripple < 10% (reverse
polarity protection)
Power consumption 3 Watt max.
Analog output 2-conductor technology
4 - 20 mA active output (max. burden 330)
or
0 - 10 V active output (min. load resistor
820)
Switching output Passive, n-switching Power MOSFET:
max. current 1.5 A, normally open
RS485 Interface 2 wire, half duplex
HSI (HYDAC Sensor Interface) 1 wire, half duplex