User guide

ContaminationSensor CS1000 Analog Output (ANAOUT)
HYDAC Filtertechnik GmbH
en
Page 59 / 100
BeWa CS1000 3247149n en 2009-02-04.doc 2009-02-04
ISO + T (ISO+T)
The ISO+T signal consists of 4 measured values which are transmitted time-coded
with the following time slices:
4,0
2,0
4,1
2,05
I (mA)
U (V)
time (ms)
4,8
2,4
19,2
High
High
Low
Low
9,6
300
3000
3000
3000
1
24
6
8
3
5
7
19,5
9,85
4,3
2,15
19,7
9,75
0,0
19,8
9,9
Time
Signal Size Signal duration
per pulse
in ms
Current (I) / Voltage (U)
1 Identifier > 4 µm(c) 300 High / Low
2 Measured value > 4 µm(c) 3000 Current/Voltage for measured value
3 Identifier > 6 µm(c) 300 High / Low / High / Low
4 Measured value > 6 µm(c) 3000 Current/Voltage for measured value
5 Identifier > 14 µm(c) 300 High / Low / High / Low / High / Low
6 Measured value > 14 µm(c) 3000 Current/Voltage for measured value
7 Identifier Temperature 300 High / Low / High / Low / High / Low / High /
Low / High / Low
8 Measured value Temperature 3000 Current/Voltage for measured value