SAE classes acc. to AS 4059
The following SAE values can be output via the analog output:
SAE A-D (
SAEMAX)
Only a single value is output.
SAE A / B / C / D
All values are sequentially time-coded before output.
SAE A / SAE B / SAE C / SAE D
Only one value is output.
SAE+T
All values are sequentially time-coded before output.
HDA.SAE
All values are sequentially time-coded before output.
Primarily this signal was planned for the HDA 5500 (HYDAC digital display Unit),
however, this can use in other applications.
The I=4.8 - 19.2 mA or voltage U=2.4 - 9.6 V DC current range depends on the
contamination class according to SAE=0.0 - 14.0 (resolution 0.1 class).
Current I SAE class / error Voltage U
I <4.00 mA Cable break U <2.00 V
4.0 mA < I < 4.1 mA Device error, device not ready 2.00 V < U < 2.05 V
4.1 mA < I < 4.3 mA Not defined 2.05 V < U < 2.15 V
4.3 mA < I < 4.5 mA Flow error (flow too low) 2.15 V < U < 2.25 V
4.5 mA < I < 4.8 mA Not defined 2.25 V < U < 2.40 V
I = 4.80 mA SAE 0 U = 2.4 V
I = 4.90 mA SAE 0.1 U = 2.45 V
I = 5.01 mA SAE 0.2 U = 2.51 V
... ... ...
I = 5.83 mA SAE 1 U = 2.92 V
I = 6.86 mA SAE 2 U = 3.43 V
I = 7.89 mA SAE 3 U = 3.95 V
I = 8.91 mA SAE 4 U = 4.46 V
I = 9.94 mA SAE 5 U = 4.97 V
I = 10.97 mA SAE 6 U = 5.49 V
I = 12.00 mA SAE 7 U = 6.00 V
I = 13.03 mA SAE 8 U = 6.52 V
I = 14.06 mA SAE 9 U = 7.03 V
I = 15.09 mA SAE 10 U = 7.55 V
I = 16.11 mA SAE 11 U = 8.06 V
I = 17.14 mA SAE 12 U = 8.57 V
I = 18.17 mA SAE 13 U = 9.09 V
... ... ...
I = 18.99 mA SAE 13.8 U = 9.50 V
I = 19.10 mA SAE 13.9 U = 9.55 V
I = 19.20 mA SAE 14.0 U = 9.60 V