The Measuring menu allows you to change settings during operation.
Selection To do
Start Measuring menu
Press
o.k.
button.
Exit without saving
Scroll to CANCEL and press
o.k.
Or automatically after 30 s without any action
Exit and save changes
Scroll to SAVE and press
o.k.
Measuring menu:
Description
DSPLAY
Select display
SWtOUT
Set switching output
ANaOUT
Select measurement category
for analog output
CANCEL
Discard changes and exit
SAVE
Save changes and exit
Display — Select display after switching on the sensor
DSPLAY
Select display
+
Description
ISO
3-digit ISO code
SAE A
SAE class A
SAE B
SAE class B
SAE C
SAE class C
SAE D
SAE class D
SAeMAX
SAE A-D
FLOW
Flow rate [in ml/min]
ANaOUT
Analog output [in mA]
DRIVE
LED current [in %]
TEMP C
Fluid temperature in °C
(Celsius)
TEMP F
Fluid temperature in °F
(Fahrenheit)