User guide

ContaminationSensor CS1000 Operating the CS1000 per keyboard (Only CS1x2x)
HYDAC Filtertechnik GmbH
en
Page 30 / 100
BeWa CS1000 3247149n en 2009-02-04.doc 2009-02-04
Operating the CS1000 per keyboard (Only CS1x2x)
After the CS1000 is switched on, "HYDAC CS1000" is displayed in moving letters,
then the firmware version is displayed for 2 seconds.
This is followed by a countdown:
WAIT99 to WAIT0.
The duration of the countdown corresponds to the set measurement time (factory
setting = 60 sec), which means that the countdown runs from 99 - 0 within the set
measurement time.
B
D
F
E
A
C
Item LED Description
A Status ContaminationSensor status display
B Display A 6-digit display that shows the selected values.
C Measurement
category
Display of the respective measurement category in the
display, i.e.:
ISO / SAE / NAS
D Additional variable Indicates the additional variable of the display value,
i.e.: Flow / Out / Drive / Temp
E Switch point 1 Indicates the status of the switching output. When lit,
the switching output is activated (closed).
F Switch point 2 Reserved for future use