CS measurement modes
After powering up, the CS1000 automatically runs in the measuring mode that has
been set.
Mode M1: Continuous measurement
Application: Stand-alone sensor
Data output: Display & RS485 & analog output
Purpose: Measurement only
Function: Continuous measurement of cleanliness class, without
switching functions
Mode M2: Continuous measurement and switching
Application: Stand-alone sensor with alarm standby display
Data output: Display & RS485 & analog output & switching output
Purpose: Continuous measurement and controlling of signal lamps etc.
Function: Continuous measurement of solid contamination, continuous
monitoring of programmable limit values; switching output is
activated to switch on the monitor display or an alarm on site
Mode M3: Filter to cleanliness class and stop
Application: Controlling a filter unit
Data output: Display & RS485 & analog output & switching output
Purpose: For cleaning up a hydraulic reservoir
Function: Controlling a filter unit, continuous measurement of solid
contamination. If pre-programmed cleanliness level is achieved
5 times in sequence, the pump is stopped.
Mode M4: Filter to continuously monitor cleanliness class
Application: Control of stationary offline filtration unit
Data output: Display & RS485 & analog output & switching output
Purpose: Establish continuous monitoring of cleanliness class between
min/max limit values
Function: Controlling a filter unit, continuous measurement of solid
contamination.
If min/max limit values are pre-programmed, the CS switches
the pump on/off to keep cleanliness within the limit value range
Mode "SINGLE" individual measurement