User guide

Condition Monitoring Unit CMU 1000 Page 42
Revised 17.12.2009 HYDAC ELECTRONIC GMBH Mat.-No.: 669749
5.2.3.3 Connection Setup with CMU 1000 using GSM Mobile Network
Start the HYDAC PC software CMWIN
In the Units Menu, select the "CM Manager" option.
If the Connection window does not open automatically, select
"Connection" in the menu bar of the CM Manager.
Mark the "Modem Connection" option in the window that opens.
Click on "Change" to open the window for the interface settings.
Make the corresponding preselection for the port settings in the window that
opens under Interface selection.
Select the respective port address and Baud rate under Interface settings.
Pressing "Refresh" causes the interfaces marked under Interface selection to
be refreshed in terms of availability.
Click on “OK“ to apply the modified settings or “Cancel“ to discard these
changes. In either case you will then return to the Connection window.
Click on "Change" to open the window for entering the telephone numbers.
Enter the telephone number of the SIM card mounted in the GSM module
CSI-F-10.
In the Pin box, input the pin code given for the SIM card which is operated in
the GSM modem in the PC (not for the SIM card in the CSI-F-10!). If no PIN
code has been assigned, then leave this box empty.