User guide

Condition Monitoring Unit CMU 1000 Page 15
Revised 17.12.2009 HYDAC ELECTRONIC GMBH Mat.-No.: 669749
Plugs Pin Channel Function I/O
1
CAN
CAN Bus Low IN / OUT
2
CAN
CAN Bus High IN / OUT
3
GND
CAN GND
4
Q
Frequency input Q IN
5
R
Frequency input R IN
6
GND
GND
7
DI 1
Digital In 1 IN
8
DI 2
Digital In 2 IN
9
GND
GND
10
AO 1
Analoge out 1 OUT
11
AO 2
Analoge out 2 OUT
X4
12
GND
GND Analoge out
1
HSI
HSI Master IN / OUT
2
RS232
RS232 OUT
3
RS232
RS232 IN
4
IO-Link
Power supply IO-Link IN
5
IO-Link
IO-Link communication IN / OUT
6
GND
GND HSI / RS232 / IO-Link
7
+U
B
Power supply +U
B
8
+U
B
Power supply +U
B
9
0 V DC
Power supply 0 V DC
10
0 V DC
Power supply 0 V DC
11
0 V DC
Power supply 0 V DC
X5
12
0 V DC
Power supply 0 V DC
1
Relay 1 NC
2
DO 1
Relay 1 COM
3
Relay 1 NO
4
Relay 2 NC
5
DO 2
Relay 2 COM
6
Relay 2 NO
7
Relay 3 NC
8
DO 3
Relay 3 COM
9
Relay 3 NO
10
Relay 4 NC
11
DO 4
Relay 4 COM
X6
12
Relay 4 NO