#8 Sheet Metal Screw
Panel A
Panel B
Panel C
Panel A
Filter Box
1/4” Bolts
3. Assemble the following parts using 6 #8 sheet metal screws. Both “B” and “C” panels should t inside the bottom “A” panel anges.
Attach “B” and “C” (side panels) to “A” (bottom panel). After the bottom and sides are assembled, attach “A” (top panel) using 6 #8
sheet metal screws provided.
4. Position the assembled lter box on rear of furnace, supporting it rmly up to electrical enclosure, covering the rear distribution blower.
Make sure the lter box is tightly pressed to the back of the furnace. Use 4 1/4” bolts (included) to rmly attach the lter box to sides of
furnace.
The lter box requires one 20” x 20” x 1” lter (not included, but
available at most hardware and home centers).
For maximum furnace efciency, inspect your lter regularly
and replace the lter when airow is restricted and the lter
appears dirty. Some environments may require more frequent
changing of the lter. Failure to replace the lter will result
in excessive temperatures causing poor performance and
damage to the furnace. It is strongly recommended to use less
restrictive, low cost lters.
7