operaTional problemS
Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 18% RH.
• The door gasket may be leaking.
Smoke in the room when opening door
• The grate in the chimney may be closed. Open the grate.
• Insufcient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or ret.
• Never open the door when there are still ames on the wood.
Uncontrollable combustion
• Faulty seal in door. Fit new seal.
• If there is an excessive chimney draft, it may be necessary to close the regulating rod. Close the
regulating rod when the stove is not in use.
• If the steel plates in the combustion chamber develop scales or become deformed, this is due to exces
-
sive heat. Stop using the stove and contact the dealer.
At interruptions that you cannot yourself rectify, you should contact the dealer.