User's manual
11
If there is risk of embers falling under the stove, the non-combustible material must also cover the oor
under the entire bottom plate of the stove as well as the area next to the stove in accordance with
national rules. The non-ammable material must be of a size that is sufcient to prevent embers from
falling out on the combustible oor.
Min. distances - uninsulated ue gas pipe:
(drawing A)
With steel cladding With stone
cladding
HWAM 4510
HWAM 4530
HWAM 4550
HWAM 4520
HWAM 4540
HWAM 4560
HWAM 4540
HWAM 4560
1. Recommended for brick wall, back, cm
10 10 10
2. Recommended for brick wall, side, cm
30 10 10
1. For inammable wall, back, cm
10 10 10
2. For inammable wall, side, cm
59 35 40
1.To inammable wall, corner installation, cm
33 7 7
3. Distance to furnishings in front, cm
120 110 110
IMPORTANT FOR UK (for all other countries please see separate text below)
• In case of wall installation, HWAM 4510/4520 must be suspended at least 17.5 cm above
an inammable oor (measured from the bottom plate of the stove). The above require-
ment applies even if the oor is tted with a oor plate.
• The variant HWAM 4510/4520 without a plinth must be installed on a BS non combustible/
constructional hearth. The non combustible/constructional hearth must extend 425 mm
in front of the appliance. It is still considered a combustible oor even if an ember catch-
ing, non-combustible oor plate is placed on top of the combustible oor. Floor in front
exceed 100°C demand closer than 425 mm in front of the stove installed without a plinth.
• Floor directly beneath the stove installed without a plinth does exceed 100°C.
Take note of the applicable regulations for the distance between the wall and ue pipe.
The distance to a brick wall is set to faciliate the servicing of the Autopilots system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a ammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
IMPORTANT FOR ALL COUNTRIES BUT UK (for UK please see separate text above)
• In case of wall installation, HWAM 4510/4520 must be suspended at least 28.5 cm above
an inammable oor (measured from the bottom plate of the stove). The above require-
ment applies even if the oor is tted with a oor plate.
• HWAM 4510/4520 without a plinth and HWAM 4510/4520 with a low plinth must not be
mounted on combustible oors. It is still considered a combustible oor even if an ember
catching, non-combustible oor plate is placed on top of the combustible oor.
• A non-combustible structure under HWAM 4510/4520 without a plinth and HWAM
4510/4520 with a low plinth must extend at least 480 mm in front of the stove.
Take note of the applicable regulations for the distance between the wall and ue pipe.
The distance to a brick wall is set to faciliate the servicing of the Autopilots system.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a ammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.