User's manual

14
14. Place the cover plate (7) so that it closes the ue outlet on top of the combustion chamber (where
the smoke ring was just removed) and afx using the three screws (8).
15. Place the rear plate (3) on the guide taps (11) on the rear side of the stove's base plate and afx the
rear plate using the two top screws (4).
16. Lie the top plate (2) on the stove.
17. Place the cast-iron or stone top cover (12) in the hole in the top plate.
18. Re-attach the front (1) to the heat storage compartment.
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are tted correctly. Make sure that
the chimney is tight and that no false draft is caused around neither the cover plate, in connection
with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that bent and/
or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of the stoves (Drawing B)
1. Bottom smoke shelf. Must rest on the steel rail at the back of the combustion chamber.
2. Top smoke shelf. Must rest on the bottom smoke shelf.
3. The steel smoke guide plate is in two parts. Each half hangs on a hook under the top plate and is
equipped with two pins (7) that serve as protection during transportation. Remember to remove
the two pins before you start using the stove.
4. Rear ue outlet. Closed at the factory using a plate afxed with screws. The ue outlet is thus concealed
behind the rear plate.
5. Removable rear plate. Must always be installed if the stove is next to a ammable wall.
6. Loose heat shield under the ash pan.
Adjustment feet
The stove comes with four adjustment feet. Mount and adjust the adjustable feet screws in accordance
with the separate instructions, 2 in each side, to the desired height.
Connecting and preparing the HWAM Autopilot IHS
TM
Before the stove can be used it must be connected and prepared. Start by connecting the power adapter
to the Airbox that sits in the space under the combustion chamber.
Air box withour power supply. Air box with power supply.
Follow the instructions in the separate manual for linking stove, room temperature sensor and app. If you
do not wish to use an app to control the stove, a remote control can be purchased. In this case, follow
the instructions in the manual supplied with the remote control. The remote control replaces the use of
room temperature sensor and app.
Before the rst lighting of the stove, it is important to run a self-test of the system to ensure that every
-
thing works as it should. See separate instructions for either app or remote control for more information.
Connection to chimney
All the stoves have both rear and top smoke outlet that can be connected to an approved steel chimney on
top or directly out at the rear to a chimney.