User's manual

48
Door/glass
A sooty glass door can easily be cleaned with a piece of moist kitchen roll dipped in ash. Go about it in
vertical movements (up and down). Follow up with a dry piece of kitchen roll. Check frequently to ensure
that seals in the door are intact and not brittle. Failing this, they should be replaced. Use original seals only.
Surface
The surface normally requires no treatment. Any damage to the coating may be remedied using a Seno
-
therm spray.
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
oPeratIonal Problems
Blackened glass
The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture
level not exceeding 18% RH.
The door gasket may be leaking.
Smoke in the room when opening door
The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door. Fit new seal.
• If there is an excessive chimney draft, it may be necessary to close the regulating rod. Close the
regulating rod when the stove is not in use.
• If the steel plates in the combustion chamber develop scales or become deformed, this is due to exces
-
sive heat. Stop using the stove and contact the dealer.
At interruptions that you cannot yourself rectify, you should contact the dealer.
declaratIon oF PerFormance
The DoP can be downloaded from our website via the following links:
HWAM 3610: www.hwam.com/dop/3610
HWAM 3620: www.hwam.com/dop/3620
HWAM 3630: www.hwam.com/dop/3630-3650
HWAM 3650: www.hwam.com/dop/3630-3650
HWAM 3640: www.hwam.com/dop/3640-3660
HWAM 3660: www.hwam.com/dop/3640-3660