User's manual
39
InstallatIon
General information
Installation of your HWAM woodburning stove must always comply with local building regulations. It is a
good idea to consult your local chimney sweep before installing the woodburning stove.
Always follow the instructions of the manual carefully and make sure that the installation is carried out
by a qualified professional.
HWAM packaging material should always be handled in accordance with the local rules for waste handling.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. A window
that opens or an adjustable air vent should be sufficient, but it is also possible to connect the stove to a
HWAM fresh air system. The air inlet/grating must be placed so that they do not become blocked.
Technical data
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand the weight
of the stove and the chimney. The weight of the chimney should be calculated according to its dimensions and
height. Weight of the stove:
Model Weight Height Width Depth
HWAM 3610c/3610m 115/112 kg 85,5 cm 55,6 cm 44,2 cm
HWAM 3620c/3620m 115/112 kg 85,5 cm 55,6 cm 44,2 cm
HWAM 3610c/3610m on a pedestal 135/132 kg 113,6 cm 55,6 cm 44,2 cm
HWAM 3620c/3620m on a pedestal 135/132 kg 113,6 cm 55,6 cm 44,2 cm
HWAM 3630c/3630m 139/136 kg 114,8 cm 55,6 cm 44,2 cm
HWAM 3640c/3640m 139/136 kg 114,8 cm 55,6 cm 44,2 cm
HWAM 3640c/3640m w/soapstone cover 229/226 kg 114,8 cm 60,0 cm 44,2 cm
HWAM 3650c/3650m 171/168 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3650c/3650m w/heat-storing stone 226/223 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3660c/3660m 171/168 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3660c/3660m w/heat-storing stone 226/223 kg 150,8 cm 55,6 cm 44,2 cm
HWAM 3660c/3660m w/soapstone cover 282/279 kg 150,8 cm 60,0 cm 44,2 cm
HWAM 3660c/3660m w/soapstone cover
and heat-storing stone
337/334 kg 150,8 cm 60,0 cm 44,2 cm
The stove is mainly made of sheet iron, with some items made of cast iron.
Test results from nominal test EN 13240
Nominal heating effect 6.0 kW
Flue gas temperature EN 13240 measurement point 292ºC
Flue gas temperature measured in the outlet socket 350ºC
Exhaust gas flow 6.0 g/s
Efficiency 78,3%
Test result based on NS 3058
Particle emissions 1,21 g/kg
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is installed
on a wooden floor or similar, the floor must be covered with a non-combustible material.
Note: HWAM 3610/3620 must always be mounted on the wall or on a plinth.