User's manual
15
opEratIonal problEms
Blackened glass
• The wood is too damp. Only use wood stored for at least 12 months under cover and with a
moisture level not exceeding 18% RH.
• Faulty seal in door. Fit new seal.
Smoke in the room when opening door
• The grate in the chimney may be closed. Open the grate.
• Insufficient chimney draft. See section on chimney or contact chimney sweep.
• Soot door leaking or dislodged. Replace or refit.
• Never open the door when there are still flames on the wood.
Uncontrollable combustion
• Faulty seal in door or ash pan. Fit new seal.
• If there is an excessive chimney draft, it may be necessary to set the regulator to its minimum position.
Also do this all when the stove is not in use.
• If the steel plates in the combustion chamber develop scales or become deformed, this is due to
excessive heat. Stop using the stove and contact the dealer.
At interruptions that you cannot yourself rectify, you should contact the dealer.
dEclaratIon oF pErFormancE
The DoP can be downloaded from our website via the following links:
www.hwam.com/dop/3520-3530