User Manual

Page 9 of 20 pages
Floor plate
European, national and local regulations must be observed in terms of the size and thickness
of a non-combustible floor covering the floor in front of the combustion chamber opening. Ask
your HWAM retailer for assistance. The combustion chamber opening is . cm wide.
Distance to combustible materials
Min. distances - uninsulated flue gas pipe (drawing A) HWAM 3120
HWAM 3130
. Recommended for brick wall
10 cm
. For combustible back wall
10 cm
. For combustible side wall
19.5 cm
.To combustible wall, corner installation,
º
10 cm
.
Distance to furnishings in front
100 cm
. For combustible wall, side, in front of the stove 40 cm
Min. distances - insulated flue gas pipe (drawing A) HWAM 3120
HWAM 3130
. Recommended for brick wall
10 cm
. For combustible back wall
7.5* cm
. For combustible side wall
19.5 cm
.To combustible wall,corner installation,
º
10 cm
.
Distance to furnishings in front
100 cm
. For combustible wall, side, in front of the stove 40 cm
*We recommend  cm to facilitate service on HWAM
®
SmartControl™
Remember to pay attention to applicable regulations concerning the required distance between
the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM
®
SmartControl
TM
.
.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should
sometimes be treated as a combustible wall, in which case we ask you to contact your local
chimney sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sucient draught and prevent any smoke nuisance. As a
general rule, satisfactory draught conditions are achieved if the chimney is  m above the stove
and at least  cm above the ridge. If the chimney is placed at side walls, the top of the chimney
should always be higher than the ridge or the tallest point of the roof. Always be aware of any
national and/or local regulations applying to thatched roofs and the location of the chimneys.
The stove requires a minimum draught of  Pa (measured at EN  measurement point). If
measured just above the smoke flue socket, the chimney draught must be - Pa.
The chimney must have a minimum clearing of Ø mm. The chimney must be provided with
an easily accessible cleaning door. The chimney and flue duct must be of flue class T and
be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing.
The required distance to combustible material must be complied with in accordance with the
brand label. Ask your HWAM retailer for further information.