User Manual

Page 14 of 20 pages
Lighting the stove
A successful combustion process requires that the wood is lit in the right way. A cold stove and
a cold chimney challenge the combustion process. Be careful to make a good lighting with suit
-
ably dry wood, using kindling and lighting the fire in the top layers of kindling. It is important to
achieve a high flue gas temperature quickly.
Open the door. Place  pieces of wood (- cm in diameter) horizontally
in the bottom of the combustion compartment (corresponding to - kg).
Place - pieces of kindling randomly on top. Place  firelighters between
the top layer of kindling. Light up the fire-lighters and close the door. Select
the desired room temperature level.
As soon as the door is opened the HWAM
®
SmartControl
TM
is activated. If lighting up does not
occur within  minutes, the HWAM
®
SmartControl
TM
will automatically go back to standby and
the dampers in the Air box will be closed.
If the smoke temperature does not reach a high enough level after lightning or stoking, the app
IHS Smart Control
TM
and the wireless room temperature sensor emit a restoking alarm, even if
there is still unburned wood and flames in the combustion chamber. The restoking alarm is emit-
ted to make you aware that the fire needs more energy. Restoking with small pieces of kindling
wood can often provide a more rapid and sucient temperature rise.
The HWAM
®
SmartControl
TM
closes all three air dampers in the Air box when the stove
is in standby mode. This prevents hot air from the room to enter the chimney (heat loss).
This might on the other hand result in a very cold chimney when the stove is lit. In certain
cases it is necessary to assist the draught in the chimney by opening the door to the burn-
ing chamber - minutes before lightning the stove. Read more on www.hwam.com
about the function of the chimney.
Important!
The ash pit must not be opened when lighting up. It must always be closed when the stove is in use.
Otherwise the HWAM
®
SmartControl
TM
does not function. The door should only be opened when
lighting up, when restoking, and when cleaning the stove. Never leave a stove before there are
lasting flames in the wood after firing!
The Thermostat Function
The HWAM
®
SmartControl
TM
will in general have an environmentally friendly combustion and
adapt to the desired room temperature. The thermostat function is designed as a radiator valve.
The user enters a desired heat level, which suits the room in which the stove is installed. When
the thermostat is set at a heat level, the control function will adapt to this temperature.
If the room temperature is lower than the desired heat level, the HWAM
®
SmartControl
TM
increases the flue gas temperature in order to increase the heat radiation from the stove.
If the room temperature is higher than the desired heat level, the HWAM
®
SmartControl
TM
decreases the flue gas temperature, thereby giving the layer of embers as long a life as
possible before restoking. This will reduce the heat radiation from the stove and facilitate
restoking without having to light up the fire anew. If the room temperature drops below the
desired level, the ember phase will be shortened, and the HWAM
®
SmartControl
TM
will activate
a restoking alarm. The HWAM
®
SmartControl
TM
will signal that a restoking is due at the flue
gas temperature of ° C, and at ° C the HWAM
®
SmartControl
TM
will enter standby mode
and all dampers will close.