User's manual

10
inStAllAtion
General information
Installation of your HWAM woodburning stove must always comply with local building regulations. It
is a good idea to consult your local chimney sweep before installing, since he will be the one to sweep
the chimney and stove.
Always follow the instructions of the manual carefully and make sure that the installation is carried
out by a qualified professional. HWAM packaging material should always be handled in accordance
with the local rules for waste handling.
Room requirements
There must be a constant supply of fresh air to the room in which the stove is to be installed. The
woodburning stove uses approx. 11-14 m
3
air per hour. In comparison, a modern cooker hood sucks
up to 1000m3 air per hour. A window that opens or an adjustable air vent should be sufficient, but it
is also possible to connect the stove to a HWAM combustion air system. The air inlet/grating must
be placed so that they do not become blocked.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes
be treated as a flammable wall, in which case we ask you to contact your local chimney sweep or glass
producer to hear at what distance the stove should be kept from glass.
Load-bearing capacity of floor
Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand the weight of
the stove and the chimney. The weight of the chimney should be calculated according to its dimensions and height.
Technical data
Model Weight Height Width Depth
HWAM 3120c/3120m 107 kg/104 kg 100.5 cm 47.9 cm 41.4 cm
HWAM 3130c/3130m 114 k g /111 k g 126.0 cm 47.9 cm 41.4 cm
Heat storing stone 32 kg
HWAM 3220c/3220m 91/88 kg 109.9 cm 47.5 cm 41.3 cm
The stove is mainly made of sheet iron, with some items made of cast iron. The HWAM Autopilot
IHS
TM
is an electronic product primarily consisting of plastic, a printed circuit board and wires.
Test results from nominal test EN 13240
Nominal heating effect 4.5 kW
Flue gas temperature EN 13240 measurement point 238ºC
Flue gas temperature measured in the outlet socket 307ºC
Exhaust gas flow 3.66 g/s
Efficiency 83.4%
The test result according to NS 3058
Particle emission 2.45 g/kg
Distance to inflammable materials
Your HWAM woodburning stove should always be installed on a non-combustible hearth. If it is
installed on a wooden floor or similar, the floor must be covered with a non-combustible material.