1. Behind
Cm. min.
2. Side
Cm. min.
3. Distance to furnishing in front
Cm. min.
4 . Above combustible oor
Cm. min.
May be installed on a 12 mm thick
hearth on combustible oor (UK)
5. Distance to combustible wall,
corner location Cm. min
.
6 . Distance to combustible wall,
corner location Cm. min.
HWAM 2610
19 36 80 3
(4)
x
(8)
34
(3)
56
(3)
HWAM 2620
19 36 80 3
(4)
x
(8)
20
(3)
42
(3)
HWAM 2630
19 36 80 - x 34
(3)
56
(3)
HWAM 2640
19 36 80 - x 20
(3)
42
(3)
HWAM 3110
10 20 80 3
(4)
x
(8)
13 34
HWAM 3120
10 20 80 - x
13 34
HWAM 3130
10 20 80 - x
13 34
HWAM 3520
10 20 80 - x
13 43
HWAM 3530
10 20 80 - x
13 43
HWAM 3630
10 40 90 - x
35
(3)
63
(3)
HWAM 3640
10 40 90 - x
20
(3)
48
(3)
HWAM 3650
10 40 90 - x
35
(3)
63
(3)
HWAM 3660
10 40 90 - x
20
(3)
48
(3)
HWAM 4510
10 59 120 28.5
(6)
x
(9)
33 57
HWAM 4520
10 35 110 28.5
(6)
x
(9)
7 31
HWAM 4530
10 59 120 - x
33 57
HWAM 4540
10 35 110 - x
7 31
HWAM 4540, stone cover
10 40 110 - x
7 31
HWAM 4550
10 59 120 - x
33 57
HWAM 4560
10 35 110 - x
7 31
HWAM 4560, stone cover
10 40 110 - x
7 31
HWAM 4620
7
(5)
/20 40
(5)
/35 130 - x
12
(5)
/12 41
HWAM 4640
7
(5)
/20 40
(5)
/35 130 - x
12
(5)
/12 41
HWAM 4640, stone cover
7
(5)
/20 45
(5)
/45 140 - x
15
(5)
/15 44
HWAM 4660
7
(5)
/20 40
(5)
/35 130 - x
12
(5)
/12 41
HWAM 4660, stone cover
7
(5)
/20 45
(5)
/45 140 - x
15
(5)
/15 44
HWAM 7150
5 31 80 - x 5 33
HWAM Classic 4
10 25 80 - x 10
(3)
39
(3)
HWAM Classic 7H
10 25 80 - x 15
(3)
43
(3)
HWAM I 30/55/HWAM I 30/55s
12/6/15
(1)
8
(1)
80 30 - -
HWAM I 30/65
4/4/14
(1)
4
(2)
80 30 - -
HWAM I 40/55
188
(7)
5
(7)
120 35 - -
(1)
Thickness of insulation, behind/under/over.
(2)
Thickness of insulation.
(3)
Important! All dimensions in connection
with corner installation are only recommendations. Contact your HETAS Engineer for a clarication.
(4)
This distance requirement is met when the stove is mounted on a plinth.
(5)
With semi-insulated ue pipe (min.
thickness of insulation: 35 mm).
(6)
This distance requirement is met when the stove is mounted on a high plinth.
(7)
Distance to non combustible insulation against combustible wall.
(8)
Can be installed on a 12 mm hearth, when
mounted on a 3 cm plinth.
(9)
Can be installed on a 12 mm hearth when mounted on low plinth.
4
2
1
3
HWAM 2610
HWAM 2620
HWAM 2630
HWAM 2640
5
6
45°
5
HWAM 4510
HWAM 4520
HWAM 4530
HWAM 4540
HWAM 4550
HWAM 4560
HWAM 3110
HWAM 3120
HWAM 3130
5
5
45°
6
HWAM 4620
HWAM 4640
HWAM 4660
HWAM 7150
5
5
45°
6
5
5
45°
6
5
5
45°
6
5
5
45°
6
HWAM 3520
HWAM 3530
5
5
45°
6
HWAM 3630
HWAM 3640
HWAM 3650
HWAM 3660
Distance to combustible materials
HWAM Classic 4
HWAM Classic 7H
5
5
45°
6
45°
5
5
6