IGSS-FMSS-L-0508 General Instructions Table of Contents This Booklet Contains Information on: FMSS-L, FMSS-L-L-Remote The FMSS-L, FMSS-L-L is a single-deck, refrigerated, self-service merchandiser, which offers additional related display when positioned in front of a “Parent” service case. The FMSS-L, FMSS-L-L only fits under Hussmann Chino Style cases. Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading.
Rev. 0508 Cut and Plan Views Drain 9 7/8" 16" (21 1/2" S.C.) Ref. Drop In Elec. 2 5/8" 4' (VARIABLE LENGTHS) 16'' Remote 21 1/2" S.C. *Dimensions adjust at theses points to match service case height 24" 4 1/2" 3 1/2" 12 1/2" n *10 1/2" *26 3/8" Fa 26'' Remote 28 5/8" S.C. 11 3/4" 6 1/8" 13 1/2" 3 7/8" Remote 8 7/8" S.C.
IGSS-FMSS-L-0508 Installation (Cont'd) NOTE: 6. Slide second case up to first case snugly. Then level second case to the first case so glass front, bumper and top are flush. A. To avoid removing concrete flooring, begin lineup leveling from the highest point of the store floor. B. When wedges are involved in a lineup, set them first. All cases were leveled and joined prior to shipment to insure the closest possible fit when cases are joined in the field.
Rev. 0508 Plumbing Waste Outlet and P-TRAP The waste outlet is located at the left hand end of these fixtures allowing drip piping to be run under the fixture lengthwise. A 1” P-TRAP and threaded adapter are supplied with each fixture. The P-TRAP must be installed to prevent air leakage and insect entrance into the fixture.
IGSS-FMSS-L-0508 Refrigeration (Cont'd) Thermostatic Expansion Valve Location This device is located on the same side as the refrigeration stub. An Alco balanced port expansion valve model is furnished as standard equipment, unless otherwise specified by customer. Expansion Valve Adjustment Expansion valves must be adjusted to fully feed the evaporator.
Rev. 0508 Electrical Wiring Color Code BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters Thermostats, and Lights. Field Wiring and Serial Plate Amperage Field Wiring must be sized for component amperes printed on the serial plate. Actual ampere draw may be less than specified.
IGSS-FMSS-L-0508 User Information (Cont'd) 8. Avoid the use of supplemental flood or spot lighting. Display light intensity has been designed for maximum visibility and product life at the factory. The use of higher output fluorescent lamps (H.O. and V.H.O.), will shorten the shelf life of the product. Important Steps 1. Do not set temperature too cold, as this causes product dehydration. Product Temperature: 33°-35°F!. Set thermostat to cut in at 28°F discharge air. Meat holding box: 32°F.
Rev. 0508 Maintenance Evaporator Fans The evaporator fans are located at the center front of these merchandisers directly beneath the display pans. Copper Coils The copper coils used in Hussmann merchandisers may be repaired in the field. Materials are available from local refrigeration wholesalers. Hussmann recommends using #15 Sil-Fos for repairs. BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT.
Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 A BALLAST 125-01-3266 FULHAM LH3-120-L CAP UNUSED RED LEAD 9/5/07 DATE: BLK # 14 D Defrost 120 V KLIXON™ THERMODISK 20420L15-913-302 L20-1.5 00003382 TO DEFROST CONTROL PANEL C Refrig 120 V RELAY MARS 90341 COIL:~115V PN:125-01-1343 2 1 RED # 14 3' CASE - ELECTRIC DEFROST FMSS-L/M CASES DRAWING #: RELAY OMRON G7L-2A-TUBJ-CB-AC24D 125-01-3182A DEFROST HEATERS (18") (2) 660W 2.
1 2 3 DATE: D Defrost ON 115 V KLIXON™ THERMODISK 20420L15-913-302 L20-1.5 00003382 2 RELAY OMRON G7L-2A-TUBJ-CB-AC24D 125-01-3182A FMSS-L/M CASES DRAWING #: PAGE 1 OF 1 W1400009 POWER: ~208/240 VAC - 1Ø - 50/60Hz. - 4W NOTE: CASE MUST BE GROUNDED L1 L2 ~208/~240VAC - 1Ø - 50/60Hz. RELAY MARS 90341 COIL:~115V PN:125-01-1343 8' CASE - ELECTRIC DEFROST-DUAL TEMP DRAWN BY: D.
CAP OFF WIRE CAP OFF WIRE BALLAST 125-01-3265 FULHAM LH2-120-L Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 1 2 3 GNL ~ 115VAC 50/60Hz. 2 1 C Case ON 115 V DATE: D Defrost ON 115 V L1 L2 ~208/~240VAC - 1Ø - 50/60Hz. FMSS-L/M CASES DRAWING #: PAGE 1 OF 1 W1400015 POWER: ~208/240 VAC - 1Ø - 50/60Hz.
BALLAST 125-01-3267 FULHAM LH4-120-L CAP OFF WIRE Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 1 2 3 2 1 C Case ON 115 V D Defrost ON 115 V DATE: L1 L2 ~208/~240VAC - 1Ø - 50/60Hz. RELAY MARS 90341 COIL:~115V PN:125-01-1343 FMSS-L/M CASES DRAWING #: PAGE 1 OF 1 W1400012 POWER: ~208/240 VAC - 1Ø - 50/60Hz.
F21T5-36" 125-03-1129 F21T5-36" 125-03-1129 F21T5-36" 125-03-1129 BALLAST 125-01-3266 FULHAM LH3-120-L Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 1 2 3 GNL ~ 115VAC 50/60Hz. 2 1 C Case ON 115 V DATE: D Defrost ON 115 V L1 L2 ~208/~240VAC - 1Ø - 50/60Hz. FMSS-L/M CASES DRAWING #: PAGE 1 OF 1 W1400016 POWER: ~208/240 VAC - 1Ø - 50/60Hz.
Hussmann Corporation, Int'l. 13770 Ramona Avenue Chino, CA. 91710 (909)-590-4910 Lic.#: 644406 CANOPY LIGHTING (2) FP28T5/830 125-03-1131 SOLENOID VALVE 225-01-3206 REVISIONS: #: DESCRIPTION: LOADING 208 V 240 V L1 11.4 12.9 11.1 L2 9.
HUSSMANN® CORPORATION 13770 RAMONA AVENUE CHINO, CA.91710 (909) 590-4910 LIC.#: 644406 DATE: RELAY MARS 90249Q 225-01-2045 LOW TEMP. T-STAT MEDIUM TEMP.
Rev. 0508 Appendices 1.3 A clogged waste outlet blocks refrigeration. The installer is responsible for the proper installation of the system which dispenses condensate waste through an air gap into the building indirect waste system. 1.4 The installer should perform a complete start-up evaluation prior to the loading of food into the refrigerator, which includes such items as: a) Initial temperature performance, Coils should be properly fed with a refrigerant according to manufacturer’s recommendations.
IGSS-FMSS-L-0508 Appendices (Cont'd) 7. Are there unusual draft conditions (from heating/air-conditioning ducts, open doors, etc.)? 8. Is there exposure to direct sunlight? 9. Are display signs blocking or diverting airflow? 10. Are the coils of the refrigerator iced up? 11. Is the store ambient over 75°F, 55% RH as set forth in ASHRAE Standard 72 and ASHRAE Standard 117? 12. Are the shelf positions, number, and size other than recommended by Hussmann? 13.
Rev. 0508 Appendices (Cont'd) d) Care must be taken when cross merchandising products to ensure that potentially hazardous vegetable products are not placed in non refrigerated areas. e) Display and storage equipment doors should be kept closed during periods of inactivity. f) Minimize the transfer time of perishables from storage to display. g) Keep meat under refrigeration in meat cutting and processing area except for the few moments it is being handled in processing.
IGSS-FMSS-L-0508 Service Record Last service date: By: _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________________________ _______________ ___________________________________________________________________________________