user manual

DEFROST MENU
3-DEFROST MENU
Press 3 on the Keypad to enter the Defrost sub-
menu.
1- VIEW/SET ITEMS
Press 1 on the Keypad to enter the V
IEW/SET ITEMS
Submenu.
This screen shows three columns:
C I R C U I T lists the defrost circuit within the
Protocol. The numbers 1 through 8 are fixed.
NAME refers to the description used to identify
the defrost circuit.
STATUS lists the status of each defrost circuit.
REFR = In refrigeration
DEFR = In defrost
DATV = DE-activated, will not defrost.
TERM = Defrost terminated by temp.
N/A = Not Available or Not Installed
The horizontal arrows are used to activate or deac-
tivate a circuit for defrost control, to force a circuit
in or out of refrigeration or defrost go to the
M
AINTENANCE MENU. Note that the DATV status
permanently disables the defrost function.
Use the vertical arrows to move up and down the
circuit list.
970307 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)
P/N 374511B
Page 23
PROTOCOL
Hand Held Device
D E F ROST MENU
1-VIEW/SET ITEMS
2-COPY SCHEDULE
3-ASSIGN OUTPUTS
4-ASSIGN CIRCUITS
FOR SPLIT SUCT
D E F ROST MENU
C I R C U I T N A M E S TAT U S
1 CIRCUIT #1 NAME R E F R
2 CIRCUIT #2 NAME D E F R
3 CIRCUIT #3 NAME DAT V
4 CIRCUIT #4 NAME R E F R
PRESS ENT TO SET
P ROTOCOL MAIN MENU
1 - S TATUS MENU
2-CONFIG MENU
3 - D E F ROST MENU
4-MAINT MENU
5-ALARM MENU