Instructions / Assembly
Operation
Ensure the regulator
adjusting knob is unlocked
when adjusting pressure. The
regulator will be damaged if the knob
is turned in the locked position..
1. Unlock the regulator adjusting
knob by pulling knob away from
the regulator.
2. Turn the regulator adjusting knob
counterclockwise until no load is on
the regulating spring.
3. Turn on the air pressure supply and
turn the adjusting knob clockwise
until the desired outlet pressure is
reached. Push the regulator
adjusting knob toward the
regulator to lock in desired
pressure.
NOTICE
11 Sp
Regulador de Presión Modelo HDA707
Para ordenar repuestos, sírvase llamar al concesionario
más cercano a su domicilio
Lista de Repuestos
1 Manómetro, 6,4 mm (1/4”) NP,
montaje trasero BC412300AV 1
2 Tapón NPT de 6,4 mm (1/4”) ST022500AV 1
3 Manómetro 11,03 bar, 6,4 mm (1/4”)
montaje inferior BC412400AJ 1
No. de
Ref. Descripción Repuesto Ctd.
Puede escribirnos a:
Attn: Parts Department
100 Production Drive
Harrison, OH 45030 U.S.A.
Sirvase darnos la siguiente información:
- Número del modelo
- Número de Serie o código con fecha (de haberlo)
- Descripción y número del repuesto según la lista
de repuestos
Technical Service
For information regarding the
operation or repair of this product,
please call 1-800-543-6400.
Installation
Disconnect power and
release all pressure from the
system before attempting to
install, service, relocate or perform any
maintenance.
1. Locate the air flow direction arrow
(See Figure 2, detail). This arrow
shows the direction of the air flow,
i.e., it points to the outlet.
2. Install the gauge. Use Teflon
®
tape
on all threads.
3. Remove plug from plastic bag. Use
Teflon
®
tape on the threads and
install securely in the port opposite
the gauge. (See Figure 3.)
4. Securely mount the regulator in any
position as close as possible to air
tool connection.
5. Verify the arrow points to the
outlet. (See Figure 2.)
6. Install the unit with the same pipe
size as the piping in use. Avoid
using unnecessary fittings,
couplings, etc., that restrict airflow.
7. Connect the air supply to the inlet
port.
!
WARNING
2
Pressure Regulator Model HDA707
Figure 2 Detail showing location of
flow direction arrow
Flow
direction
arrow
2
1
6, 7, & 8
4
5
Figura 3
Lista de Repuestos Opcionales*
4 Ménsula modular PA117600AV 1
5 Ménsula para pared PA117500AV 1
6 Adaptador modular de tubería de
6,4 mm (1/4”) BC411900AV 1
7 Adaptador modular de tubería de
9,5 mm (3/8”) BC412000AV 1
8 Adaptador modular de tubería de
3,2 mm (1/8”) BC412100AV 1
*Se vende por separado
No. de
Ref. Descripción Repuesto Ctd.