Use and Care Manual
10
11
Operation(Continued)
HUSKYTOOLS.COM
Clearing jams
4
Occasionally,afastenermaybecomejammedinthefiring
mechanismofthetool,makingthetoolinoperable.To
removeajammedfastener,followthesestepsbelow:
Disconnectthetoolfromairsource.
Removefastenersfromthetool.Failuretodosowill
causethefastenerstoejectfromthefrontofthetool.
Pull up on the latch(D) and open the jam release(E).
Using caution not to bend or damage the driver blade,
using pliers or a screwdriver if required to clear the
jammed fastener.
Close the jam release and latch.
Reconnect the tool to the air source.
Reload the tool with fasteners.
WARNING: Makesurethereisnofastenerin
magazinebeforeclearingajam.
WARNING:Disconnectthetoolfromtheairsource
wheneverclearingajam. Afterdisconnectingthe
toolfromtheaircompressor,there,shouldstillbe
enoughairpressuretofirethetool.Aftertheair
hoseisdisconnected,alwaysfirethetoolintoscrap
woodrepeatedlytomakesureallofthe
compressedairisexpended.
Please contact 1-888-HD-HUSKY for further assistance.
Operation(Continued)
WARNING:Keepthetoolpointedawayfromyourself
andotherswhenloadingfasteners.Failuretodoso
couldresultinpossibleseriouspersonalinjury.
WARNING:Useonlyfastenersrecommendedfor use
withthistool.Fasteners not identified for use with this
tool by the tool manufacturer are able to result in a risk
of injury to persons or tool damage when used in this
tool.
WARNING: Neverloadfastenerswiththeworkpiece
contactortriggeractivated.Doingsocouldresultin
possibleseriouspersonalinjury.
3
Unloadingfasteners
Unloadingisthereverseofloading. Alwaysdisconnectthe
air sourcebeforeunloading.
WARNING: Alwaysunloadallfastenersbefore
removingtoolfromservice.
WARNING:Alwaysdisconnecttheairsourcebefore
unloading.
Latch(D)
Jamrelease(E)
Non-marring pad
5
The non-marringpadattached to thenoseofthetool
helpspreventmarringanddentingwhenworkingwith
softerwoods.
WARNING:Disconnectthetoolfromtheairsource
beforeremoving orreplacingthenonmarringpad . -
Failuretodosocouldresultinseriouspersonal
injury.
Setting the air pressure
6
Theamountofairpressurerequireddependsonthe
sizeofthefastenersandtheworkpiecematerial.
Begin testing the depth of drive by driving a test nail into
the same type of workpiece material used for the actual
job.
Drive a test fastener with the air pressure set at 90-95 psi.
Raise or lower the air pressure to find the lowest setting
that will perform the job with consistent results.
It may be possible to achieve the desired depth with air
pressure adjustments alone.
ToremovethepadPull the no mar tip towards the back :
of the tool following the nose.
ToreplacethepadPush the no mar tip on to the tool :
inserting the opening of the no mar tip on to the nose.
Depth adjustment
7
The driving depth of the fasteners are adjustable. To adjust
the depth, use the drive depth adjustment wheel (F) on the
tool.
Disconnect the tool from air source.
Turn the depth wheel left or right to change the driving
depth.
Reconnect the tool to the air source.
Drive a test nail after each adjustment until the desired
depth is set.
Turn the adjustment knob clockwise
Flush
Too Shallow
Adjustment
wheel(F)
Too Deep
Flush
Turn the adjustment knob count clockwise
Adjustment
wheel(F)
CAUTION:It is advisable to test the depth on a scrap
workpiece to determine the required depth for the
application.
To determine depth of drive, first adjust the air
pressure and drive a test fastener. Never exceed 110