Owner's Manual
Fuel Type Test and warranty for Diesel Exhaust
Fluid dispensing only
Flow Rate 10 gpm / 37.9 Lpm
Body Plastic
Disc Fluorocarbon
Packing Double O-ring seal protected by ber
reinforced Teon
Lever One piece contoured steel
Shipping Weight 1.5 lbs / .7 kg
Threads 1" / 25.4 mm BSPP
Spout ¾" / 19 mm O.D.
Case Quantity 15
GENERAL TECHNICAL DATA
CLEANING INSTRUCTIONS
TROUBLESHOOTING GUIDE
Nozzle keeps shutting off or won't dispense... 1. Make sure dispenser is on and activated.
2.Slowdownowrate-uselowernotchonclip.
3. Clean spout tip end.
4.Cleanorreplacelter.
5.InspectSafe-T-Break
®
.
6. Replace spout assembly.
7. Clean loss motion diaphragm cartridge assembly.
Nozzle won't shutoff... 1.Checkowrate-minimumof3gpm/11.4Lpmrequired.
2. Remove nozzle and drain hose.
3. Check vacuum cap screws are tightened securely.
Nozzle leaks... 1. Check for loose spout.
2. Check hose connection.
3. Check for cracks in nozzle and hose threads.
Lowowrate... 1.Verifydispenserisnotinslowowmode.
2. Check for system leaks.
Husky Corporation • 2325 Husky Way • Pacic, MO 63069 • Phone: (800) 325-3558 • Fax: (636) 825-7300 • www.husky.com
Page 3 009351-2 6/2013
1. Activate dispenser.
2. Insert spout into ll pipe opening.
3. Lower hose end of nozzle so the spout ring catches the inside
of the ll pipe.
4. Raise the lever and begin dispensing.
5. Nozzle will shut off automatically when the tank is full.
6. Wait 15 seconds to allow any uid remaining in the spout to
drain.
7. Remove nozzle from ll pipe by raising hose end of the nozzle.
8. Return nozzle to nozzle boot.
OPERATION INSTRUCTIONS
HOLD OPEN CLIP INSTRUCTIONS
Model #3593 Hold Open Clip Kit
INSTALLATION
1. Remove nozzle from hose and drain.
2. Position latch spring under latch clip and hold them in place.
The latch clip should straddle the mating holes in the trigger
lever.
3. Insert latch rivet through latch clip and lever, making sure latch
spring is secured in position by the rivet.
4. Install push nut on rivet - DO NOT hammer in place.
5. Squeeze lever several times to check operation.
6. Verify clip and lever are parallel.
REMOVAL
1. Remove nozzle from hose and drain.
2. Place nozzle on a at surface in safe location.
3. Hold up on the latch clip to prevent rivet from rotating.
4. Drill off the riveted end using a 1/4 in / 6.4 mm bit.
5. Remove clip, rivet and torsion clip spring.
6. Do not remove latch plate.
1. Remove nozzle from hose and drain.
2.Removenozzleguardandwafesplashguard(ifapplicable).
3. Remove spout assembly.
4.Cleanthespoutassembly-pourdeionizedwaterintoendof
theventtubetoushboththeventtube.
5. Flush all internal passages and external parts with deionized
water.
6. Flush vacuum passages and external parts with deionized
water.
7. Inspect spout assembly for damage.
8.Replaceanydamagedorcrackedo-rings.
9. Reinstall spout assembly.
10. Reinstall nozzle to hose according to the manufacturers
installation instructions included on page 1 of this document.
Only clean DEF products with deionized water.
Do not reinstall damaged spout assemblies or cartridges.