Operation Manual

26
SPECIFICATIONS .....................................................................................................................
Models
230VAC Transformer Version
Outdoor Cabinet Types
EC-401-E: 4 station
EC-601-E: 6 station
EC-401-A: 4 station Australian plug
EC-601-A: 6 station Australian plug
Indoor and Line In/Line Out External Transformer
EC-201i-E: 2 station European plug
EC-401i-E: 4 station European plug
EC-601i-E: 6 station European plug
EC-201i-A: 2 station Australian plug
EC-401i-A: 4 station Australian plug
EC-601i-A: 6 station Australian plug
110VAC Transformer Version
Outdoor Cabinet Types
EC-400: 4 station
EC-600: 6 station
Indoor and US Plug-in Transformer
EC-200i: 2 station
EC-400i: 4 station
EC-600i: 6 station
Operating Specifications
Station Run Time: 0 to 4 hours in 1-minute increments
Start Times: 4 per day, per program, for up to 12 daily starts
Watering Schedule: 7-day calendar or interval (1 to 31 day) pro
-
gramming
AM/PM or 24 hour clock option
Start time stacking
Simple manual operation, including 1 button manual operation
Seasonal Adjustment: 10 to 150% in 10% increments
Electrical Specifications
Transformer Input: 230VAC, 50Hz International Use
Transformer Output: 240VAC, 0.600 amps
Station Output: 24VAC, .28 amps per station
Maximum Output: 24VAC, .56 amps
Master Valve Output: 24VAC, .28 amps
Battery: Not required for program backup. 9-volt alkaline battery
(not included) may be used to program controller in absence of
AC power.
Electronic short circuit protection
Surge protection: primary MOV-type
Non-volatile memory for program data
Controller will track time for 4 weeks in event of a power outage
(even without a 9 volt battery)
Rain sensor override by manual operation
Three Programs: A, B and C