Operation Manual
SEASONAL ADJUSTMENT
MANUAL-ONE STATION
1
MANUAL-ALL STATIONS
ALL
AUTOMATIC
21
NOTE: Due to variances in pressure and flow, valve may
take up to one minute to fully close.
Bypass Weather Sensor
If there is a weather sensor installed that is interrupting irrigation, you
can bypass it by using the manual watering options described below.
The dial positions MANUAL-ONE STATION and position MANUAL-ALL
STATIONS as well as the One Touch Start and Advance process will
successfully bypass the rain sensor.
Seasonal Adjustment
Seasonal Adjust is used to make
global run time changes without
re-programming the entire controller.
This feature is perfect for making
small changes that are necessary
as the weather changes without reprogramming the entire controller.
For instance, hotter times of the year may require a bit more water.
Seasonal adjust can be increased so that the stations will run longer
than the programmed time. Conversely, as Fall approaches, the
seasonal adjust can be reduced to allow for short watering durations.
To use the seasonal adjustment feature:
1. Turn the dial to the SEASONAL ADJUSTMENT position.
2. The display will now show a flashing number followed by a %, as
well as the bar graph which always remains on the display. Press
the or buttons to adjust the percentage of the seasonal ad-
justment. Each bar on the graph represents 10%. This feature can
adjust the controller from 10% to 150% of the original program.
To view the new adjusted run times, simply turn the rotary dial to
the SET STATION RUN TIMES position, the displayed run time will be
updated accordingly as the seasonal adjustment is made.
NOTE: The controller should always be initially pro-
grammed in the 100% position.
Manually Run a Single Station
1. Turn dial to the MANUAL-ONE
STATION position.
2. Station run time will flash in the
display. Use the
button to
move to the desired station. You may use the or button to
select the amount of time for a station to water.
3. Turn the dial clockwise to the AUTOMATIC position to run the
station (only the designated station will water, then the controller
will return to automatic mode with no change in the previously set
program). Also see One Touch Manual Start and Advance on
page 22.
Manually Run All Stations
1. Turn dial to MANUAL-ALL
STATIONS.
2. Select program A, B, or C by
pressing the
button.
3. Press the
button until desired starting station is displayed.
4. Station run time will flash in the display. Use the
or button
to select the amount of run time for the station to water if different
from the run time displayed.
5. Use the
button to move to the next station.