Operation Manual
C
A
B
6
MOUNTING THE INDOOR CONTROLLER TO WALL ..........................................................
NOTE: The indoor EC is not water or weather resistant,
and must be installed indoors or in a protected area.
1. Select a location as close as possible to a standard electrical
outlet, one that is not controlled by a light switch. The location
should be protected from moisture and direct sunlight.
2. Place the controller at eye level. Use the hole at the top of the
controller as a reference and secure one 25 mm screw (A) into
the wall. Note: Install screw anchors if attaching to drywall or
masonry wall.
3. Align controller with the screw and slide the keyhole (B) on top of
the controller over the screw.
4. Secure controller in place by installing screws in the holes (C)
below the terminal strip area.
Do not plug transformer into power source until the con-
troller is mounted and all valves have been connected.
Installing the Conduit Cover
(For indoor controller installations)
The Conduit Cover is provided to
cover the field wires as they exit
the conduit into the bottom of the
controller. The conduit cover can
be used with ½" or ¾" diameter
conduit.
To install the Conduit Cover:
1. Remove the lower access
panel on the EC.
2. Slide the Conduit Cover on the
bottom edge of the controller.
3. Bring the conduit and field wires to the bottom of the controller.
Make sure that there is a sufficient length of conduit so it enters
the Conduit Cover. There are two small notches on the left side of
the cover to route the 24VAC wires from the external transformer,
or wires from the sensor and P/MV (if applicable).
4. Secure the Conduit Cover to the wall with the screws and anchors
provided.
5. Replace the lower access panel on the EC.
Conduit
Cover