SET UP FLOW MONITOR
The Flow Monitor requires the following information to
operate correctly:
Install and set up a ow sensor (Devices menu).
Install and set up a P/MV (Devices menu).
Set up a Flow Zone, and complete all information for the
Flow Zone (Flow menu).
Attach each station to a Flow Zone (Station Setup menu).
Learn ow for all stations with run times (Flow menu).
FLOW ZONES
A Flow Zone denes a section of pipe and a group of stations
attached to that pipe, which is managed as a hydraulic unit.
Flow Zones are used for both Flow Manager and Flow Monitor.
Each Flow Zone has a check box for “Manage Flow” and
“Monitor Flow. To monitor ow, check that box. Then
complete the settings and rules for the Flow Zone.
Overflow/Underflow Alarm Limits: ACC2 sets the over
and underow limits for each station’s learned ow at the
ow zone level. Enter the maximum and minimum ow
percentages you want the Flow Zone to allow for the stations
attached to the Flow Zone. If these limits are set too close to
100%, there is a greater chance of false alarms, due to natural
uctuations in the ow.
FLOW MAP
In the Flow Zones menu, press the so key for Flow Map. This
tells the controller how the Flow Zone is connected, and which
devices are used in that hydraulic unit. All stations must be
downstream from the ow sensors and master valves that are
checked here.
Flow Sensor Assignment: Check the box for the Flow Sensor
or sensors connected to the Flow Zone.
If an X is in one of the Flow Sensor boxes, the sensor has
already been assigned to another Flow Zone, and is not
available for this Flow Zone.
If a Flow Sensor number does not appear, it has already been
assigned to a MainSafe, and is not available for Flow Zone
monitoring.
P/MV Assignment: Check the box for the Master Valve that is
installed in line with the ow sensor on this ow zone.
If an X is in one of the P/MV boxes, it has already been
assigned to another Flow Zone, and is not available for this
Flow Zone.
If a P/MV number does not appear, it has already been
assigned to a MainSafe, and is not available for Flow Zone
monitoring.
MainSafe™ Assignment: If using this optional feature, select
the MainSafe zone that is upstream from the Flow Zone. If
MainSafe is not being used, leave this set to “None.
The selected MainSafe ow sensor and P/MV assignments
are shown at the bottom of this screen.
Flow Operations