Quick Start Guide
28 hunter.direct/ACC2help
STATION LOGS
Station logs record every single event that occurs in the
controller (up to 1500 events), beginning with the most
recent. This can be useful for advanced troubleshooting, or to
verify that a station actually watered.
FILTER LOGS
This allows any of the three logs to be ltered by date, or by
record number.
EXPORT LOGS
CLIK SENSOR DIAGNOSTICS
• Sensor: Shows each sensor and name.
• State: Shows the current status of the sensor.
- “Inactive” means the sensor is normal.
- “Active” means the sensor is currently alarmed.
- “Delayed” means the sensor was recently alarmed,
and is now inactive, but a Rain Delay is in eect for the
sensor.
- “Disabled” means the check box for the sensor (Devices
menu) is unchecked, and no responses will be caused by
the sensor.
• In Use?: Shows whether the sensor is currently set to shut
down any programs in the Sensor Response menu.
MODULE INFO
Select Module Info to see the current version of all rmware
in all modules and components. Module slots or components
that are empty or not reporting are shown as Not Present.
So keys allow shortcuts to other diagnostic checks, which
are also available directly from the Diagnostics menu.
When the facepack is reversed in the frame, it will
automatically go to the Module Info screen. The facepack
is still fully operational, and pressing the Home button can
access all programming functions when the facepack is
reversed. The controller will still run automatically if the
facepack is le reversed.
All logs can be written to the SD card, described in
the Advanced Features section. Advanced Features
section on page 30.
Diagnostics Menu