Pulse type: enter the amount equal to a single pulse.
Enter the information for each ow sensor that is connected
to a ow terminal. There are copy and paste so keys
available, if all the meters are the same type and size.
Once this information is entered for each ow sensor input,
the controller is ready to read ow. However, each ow sensor
must be attached to a Flow Zone (Flow, Flow Zones) before
real time monitoring can occur.
Flow Totals may be viewed at the Flow menu.
Current ow rates (by sensor) can be read from the Home/
Activity screen with the View Flow so key.
Flow Monitoring: Additional setup for station level ow
monitoring is required in the Flow menu (Flow Zones), and in
the Stations, Station Setup menu.
Stations Menu
STATION SETUP
Allows stations to be named. Most other functions are
described in more detail in the Flow Operations section.
Station P/MV Usage indicates which normally-closed P/MV
outputs the station will activate, whenever it runs.
Station Flow Zone assignment (required for Flow Manager
and/or Flow Monitoring).
Flow Priority (used in Flow Manager). Check the box to make
a station more likely to water earlier in ow management.
Flow Rate: Enter or learn the typical ow for the station. Used
in both Flow Manager and Flow Monitor. See Flow Operations
section on page 32.
Delay: Sets the amount of time the station can run before
high or low ows will cause an alarm. Set longer delays for
stations that take longer to stabilize ow.
P/MV boxes with the “X” are unavailable, because they are
already assigned to other Flow Zones or MainSafe™ zones.
Stations Menu