Quick Start Guide

20 hunter.direct/ACC2help
SOLAR SYNC
Aer connecting a Solar Sync sensor to the controller, set up
operation in the Devices, Solar Sync menu.
Check the box to Enable Solar Sync.
Choose the Region and set the Water Adjustment,
according to the Solar Sync manual instructions.
For normal operations, this is all that is necessary. It will
take the Solar Sync two or three days to register enough
climate data to begin adjusting.
Solar Sync Delay allows a number of days to wait before
automatic Solar Sync adjustment goes into eect (to establish
new landscape, for example). Enter a number of days (1-250)
to wait, and specify the Adjustment During Delay percentage
to use during the delay period. At the end of the delay, the
Solar Sync will begin adjusting automatically for the current
climate conditions.
The delay does not interfere with the Solar Sync Rain and
Temp functions. They are still able to perform shutdowns on
rain or freeze events during this delay.
Complete the setup by setting the programs to use Solar Sync
in the Program, Seasonal Adjust menu.
FLOW SENSORS
Aer connecting one or more ow sensors to the controller,
set up operation in the Devices, Flow Sensors menu.
Select the sensor input number to be setup (1-6). The
controller has 3 Flow Sensor inputs built in, but 3 more can be
added with the A2C-F3 Flow Expansion module.
Check the box for either “Hunter” or “Other” ow meters.
If Hunter is checked, move to the Model eld and select the
Hunter FCT model number for the diameter of the pipe. This is
all that is necessary to calibrate the setup.
If Other is checked, you must select the Flow Sensor Style
and enter the calibration information. Some use K-factor and
Oset, and others are Pulse type. Consult the ow meter
suppliers documentation for the correct settings or contact
Hunter Technical Support for additional information.
K-Factor and Offset: obtain these values from the ow sensor
manual, and enter here.
Basic Programming and Setup