Quick Start Guide
Built on Innovation
®
19
SENSOR RESPONSE
Located on the Devices menu, Sensor Response sets which
sensors will shut o which programs in basic operations.
The sensor responses are set up for each program, one
page at a time. If you want the same responses for multiple
programs, set up the responses for the rst program, then
click the Copy so key. You can then change the program
number and click the Paste so key to duplicate the settings.
There are three standard Clik sensor inputs on the Power
Supply Board. If a Hunter Solar Sync sensor has been
congured, there are also settings for Solar Sync Rain and
Freeze.
Ignore: Program does not respond to the sensor.
Suspend (recommended): Program suspends watering when
sensor is active (alarmed) but keeps track of time. If the
sensor returns to normal, the suspended program will resume
irrigating where it should be at that time in the schedule. The
program will end when it was originally scheduled to end.
Pause (use caution): Program stops where it is, when the
sensor is active. If the sensor returns to normal, the program
will resume watering where it le o. This will cause the
program to end much later than the original schedule.
It is not possible for a program to be set to both Pause and
Suspend for dierent sensors, because they cannot both be
active at the same time. If you change a response setting for
a sensor, and another sensor for the same program changes
automatically, this is by design.
Rain Delay: In the Sensor Response menu, press the so key
for Rain Delay. This optional setting will cause watering to stay
o for a set number of days aer the sensor activation is over.
Select the number of days for watering to stay o for each Clik
sensor input.
Basic Programming and Setup