Quick Start Guide

18 hunter.direct/ACC2help
P/MV OPERATION PUMP/MASTER VALVE
OPERATION
Dial to the Devices menu, and select P/MV Operation. Each
P/MV will be checked for Normally Closed operation. This is
a station level setting, meaning that the P/MV is activated
by stations when they begin to run. The Station Setup menu
allows you to set each station for the P/MV outputs it needs
to run water.
Normally Open may also be selected, and is discussed further
in the Flow Operations section. Normally Open is not a
station level setting. The valve is always open until a problem
is detected at the Flow Zone, or MainSafe level, when the
controller activates the normally-open P/MV to shut the
water o.
P/MV Off Delay: This sets how long the P/MV output will
remain active aer a station stops calling for it (for example,
during Delay Between Stations). It is preset to 15 seconds, but
can be changed (use caution). Hunter is not responsible for
damage to pump components when longer delays are set.
P/MV Diagnostics: Press the so key for P/MV Diagnostics to
view the status and current draw of each active P/MV output.
P/MVs that are not running are not shown.
SENSORS
Rain shuto and other sensors must be setup in the Devices
menu.
CLIK SENSORS
Dial to the Devices menu, and select Clik Sensors for basic
Hunter “Clik” sensors.
To set up a sensor, click the box for Enable Sensor.
The ACC2 sensor inputs are already congured as Normally
Closed, but this can be changed for other types of contact-
closure sensor inputs to Normally Open.
It is also possible to enter a name for individual sensors.
Basic Programming and Setup