Prep Connect Complete Channing Installation Manual Model: 52151 Matte Black 52155 Fresh White 52168 Matte Silver Fan weight ±2 lbs: 23.8 lbs (10.8 kg) ©2022 Hunter Fan Co.
Congratulations on purchasing your new Hunter® ceiling fan! The ceiling fan you purchased will provide comfort and performance in your home or office for many years. This instruction manual contains complete instructions for installing and operating your fan. We are proud of our work and appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world. We are here to help! This Instruction Manual is designed to make installation as simple as possible.
Tools Needed for Installation Box Outlet Mount Building Structure Mount 9/64" Box Contents Parts Included Hardware Included A Canopy Mount AA B Canopy C Fan Body H Wood Screw x2 Small Flat Head Screwdriver Jumper Harness BB Washer x2 D Snap-on Blades x5 E Glass Cover x4 F G Light Bulb x4 Pull Chains threadlocker 3
Before Beginning Installation Standard Mount OFF ON ON ON OFF OFF ON OFF OFF Turn Power OFF, breaker and light switch. This installation is for flat ceilings using the short pre-installed downrod ceiling fans. WARNING To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location. IMPORTANT The longest accessory downrod that can be used with HunterExpress® fans is 12-inches.
a Installation – Canopy Mount and Terminal Wiring 1a Building Structure Mount 1 A Prep BB • You must be able to secure the fan to building structure or fan-rated outlet box. • You have two options for installation. Pick which one works best for your location. Remove any existing bracket prior to installation. AA 2 Using wood screws (AA) and washers (BB) included, install canopy mount (A) through box outlet into building structure.
Installation – Canopy Mount and Terminal Wiring (continued) 1b Single Switch Wiring Green, Green Yellow Stripe, or Bare (grounding) Connect wiring from ceiling to terminal block (on side of canopy mount) and tighten using flathead screwdriver (included). For single switch wiring an additional jumper harness component will be needed in step 2b. White (grounded) WARNING The ceiling fan must be grounded.
Prep Installation – Fan Body, Wiring Harness, Canopy Cover, and Blades Connect 2a 2b A A 2 B 1 Complete B H C B NOTICE 2c Note: For single switch wiring an additional jumper harness component will be needed. Take the jumper harness (H) from the accessories bag. Connect the female end to the hanging bracket connector. Connect the male end of the jumper harness to the ceiling fan connector. C To prevent damage to fan, ALWAYS lift holding either the fan housing or the downrod.
Connect Installation – Glass Cover 3b Complete F Install a bulb (F) into each of the sockets. When necessary, replace with bulbs of same wattage. WARNING 3a GLASS FALL HAZARD To prevent SERIOUS INJURY or DEATH, make sure that glass is properly secured. ON OFF ON ON OFF OFF ON OFF 1 ON 2 E To install the shade, first loosen the thumb screws (C). Raise the shade (E) to the light fixture (C). Tighten all thumb screws securely. 8 Turn Power ON, breaker and main switch.
Installation – Pull Chains 3c Feed the pull chains from the fan switch and the light switch down through the holes in the upper switch housing as shown. Attach the pull chain pendants to the light and fan pull chains. Repeat x2 The fan pull chain controls the speed: from high to off. The light pull chain controls the light fixture: on and off.
Reversing the Fan Reverse Switch Updraft (clockwise rotation) creates a more indirect airflow. Updraft airflow is great for moving warm air downward. Downdraft (counterclockwise rotation) creates a direct breeze and maximum cooling effect. Ceiling fans work in two directions: downdraft (counterclockwise rotation) and updraft (clockwise rotation). To change the direction of air flow, turn the fan off and let it come to a complete stop. The reversing switch is located inside the light fixture.
Troubleshooting Fan Does Not Work • Make sure power switch is on. • Check the circuit breaker to ensure the power is turned on. • Make sure the blades spin freely. • Turn off power from the circuit breaker, then loosen the canopy and check all the connections according to the wiring diagram. Excessive Wobbling • Make sure the blades are properly installed on the blade iron posts. • Turn the power off, support the fan carefully, and check that the hanger ball is properly seated.
Installation - Long Downrod 1 2 2 3 4 5 9 4 2 6 8 10 5 10 1 7 3 1. Loosen set screw (1) and remove ball screw (2). 2. Slide ball down (3), remove small metal pin (4) and ground screw (5). 3. Slide down inner sleeve (6). Place screwdriver through hole in downrod (7) making sure not to hit or twist wiring. Twist screwdriver counter-clockwise to break downrod free. 4. Remove ball, inner sleeve and downrod from fan body (8) and wiring 6 10 8 9 2 7 10 4 10 7 harness. 5.