Installation guide

9
42486-01 • 03/06/12 • Hunter Fan Company
Receiver DIP
switches
Transmitter
Jumpers
CFL Toggle Switch
CFL
Receiver 1
Receiver 2
Example DIP Switch Settings
DIP Switches
Set to 1111
DIP Switches
Set to 0111
4321 4321
4 = on (fermé)
3 = on (fermé)
2 = on (fermé)
1 = off (ouvert)
4 = on (fermé)
3 = on (fermé)
2 = on (fermé)
1 = on (fermé)
Example Jumpers Settings
Transmitter 2Transmitter 1
4-1. IMPORTANT! B e f o r e y o u c h a n g e t h e J u m p e r s e t t i n g s , m a k e
sure the battery is not connected to the transmitter.
Change the position of the jumpers in the transmitter and the
DIP switches in the receiver. Be sure the position of the jumper
in the transmitter matches the position of the DIP switches
in the receiver. If they don’t match, the controller will not
function. For instructions on how to set the jumpers, read the
box below.
4-2. ere is a toggle switch beside the DIP switches on the
transmitter. Move the toggle switch toward the side that
reads “CFL” if you are going to operate the fan with CFL bulbs.
Move the switch to the “INC” side if you are going to use
incandescent bulbs.
4-3. Install the 12-volt battery into the transmitter.
Setting DIP switches and Jumpers
When two or more fans are located near each other, you may desire
to have the receiver/transmitter for each fan set to a dierent code,
so that the operation of one fan does not aect the operation of
the other fans.
e DIP switches for the receiver are located on the at surface
of the receiver. e Jumpers for the transmitter are in the battery
compartment.
CAUTION: e remote control device complies with part 15 of the FCC rules.
Changes or modications not expressly approved by Hunter Fan Company could void
your authority to operate this equipment.
Operation is subject to the following two conditions:
1. is device may not cause harmful interference.
2. is device must accept any interference received, including interference that may
cause undesired operation.
Note: Use with a fan that incorporates an air gap switch (normal on-o wall switch).
WARNING: Maximum fan load is 1.5 Amp; maximum lamp is 120 Watts.
4 Setting the Remote Transmitter and Receiver