User's Manual
26
Ifthestationisconnectedtoapressurizedvalve,thewaterwillturn on.TakecaretokeeptheICD‐HPoutofthewater
fromsprinklers.
Press‐toturnastationoff.ThestationwillturnoffandtheStatewillchangefromOntoOffaftera
fewseconds.
ImportantNote:TheICD‐HPcannotsetaruntimeforadecoderactivation.TheACCcontrollerwillsendanOffcommand
downthetwo‐wirepathonceperminute,whennostationsaresupposedtoberunning.Ifyouturnastationonwiththe
ICD‐HP,this
controllercommandwillturnthatstationbackoff,withinaminute.
Iflongerruntimesarerequiredfordiagnosticpurposes,turnanotherdecoderstationonfromtheACCcontroller,orwith
aremotecontrol(ICR,ROAM,orMaintenanceRadio).Aslongasthisstationisrunningfromthecontroller,the
“off“
commandwillnotbesenteveryminute.
Ifanotherstationisrunningfromthecontrollerasdescribed,andastationinthefieldisturnedonwiththeICD‐HP,itwill
runforapproximately12minutes,oruntilitisturnedofffromtheICD‐HP.
GetDecoder
Status:ThisallowsquickaccesstothesamestatusmatrixforoutputsastheGetDecoderStatuscommand
fromtheDecoderProgrammingmenu.
ThiscanbeusedtoviewthecurrentdrawofasolenoidafterithasbeenturnedonwiththeTurnStationOn/Off
commandfromtheICD
‐HP.Turnthestationormultiplestationson,thenuseGetDecoderStatustoviewthecurrent
drawonthedecoder.