Active:Showswhethertheoutputiscurrentlyturnedon(Y=Yes,N=No).
SensorDecoders:IfthedecoderfoundduringGetDecoderStatusisaSensorDecoder,thedisplaywillshowthestatusof
eachsensorinputtothedecoder’sPorts,onindividualscreens.
Usetheleftandrightarrows
toseeeachPort(AandB)individually.
Cliksensors:ThedisplaywillshowthecurrentstateoftheClikinputas
Closed(normal)orOpen(alarmed).
Flowsensors:Thedisplaywillshowthetypeofflowsensor(setfromthe
controller),thesizeorKFactorandOffset,
andthecurrentactualflowin
GPMorLPM(dependingonUnitofMeasurementsettings).
TheICDHPisnotusedtosetorchangeflowsensorsettings.Itshowswhat
thecontrollerhassenttothesensordecoder,anddisplaysthecurrentflow.
Theflowsensorisalwaysconnectedto
PortAofthesensordecoder.Use
theleftandrightarrowstoviewPortB,whichcanbeusedforCliksensor
inputs.
Theflowreadingwillupdatechangesinflowlive,inthescreendisplay,as
SENSOR STATUS #
----------------------
Port A Type: Clik
State: Closed
/ To Change Port
SENSOR STATUS #
----------------------
Port A Type: FLOW
Sensor: HFSFCT150
Flow Rate: xxxx.x GPM
/ To Change Port