ImportantNotes:
Outputsmaybeassignedfrom000to500.Donotassignastationnumberhigherthanthecapacityofyourcontroller,or
itwillnotoperate!(Example:ACC99Dhas99stationcapacity.Donotprogramastationnumberhigherthan99).TheICD‐
HPdoesnotknowthecapacityof
yourcontroller.
ReservedStations:Itispossibletoassign“000”toadecoderoutputwiththeICD‐HP.Thisoutputwillnotbeused.
However,itmaybeprogrammedatalaterdate,toaddanewstationtoa
multi‐stationdecoder.
Forexample,asix‐stationdecodercould
haveoutput#6(oranyother
outputs)settostation000.The000outputswouldnotbeoperational,but
couldbereservedforfutureadditions.Thenthenewstationnumbercould
beassignedtothereserved000outputwiththeICD‐HP.
Donotassignastation000unlessyouwish
toskipastation,orreserveone
forfutureexpansion.Stationnumber000cannotbeturnedonbya
controller!
StationsinRandomOrder:Itispossibletoassignanyvalidstationnumbersinanyorder.TheICD‐HPcanenterany
stationnumbersinamulti‐stationdecoderin
anyorder.Thiscannotbedonefromthecontroller’sdecoderprogramming,
butisanaddedfeaturewithICD‐HP.
-PROGRAM A DECODE
R
--
Output 1: Sta-001
Output 2: Sta-032
Output 3: Sta-025
Output 4: Sta-081
Output 5: Sta-014
Output 6: Sta-000
Press 3 To Program
SampleICD‐600displaywithrandomstation