User's Manual

18
ImportantNotes:
Outputsmaybeassignedfrom000to500.Donotassignastationnumberhigherthanthecapacityofyourcontroller,or
itwillnotoperate!(Example:ACC99Dhas99stationcapacity.Donotprogramastationnumberhigherthan99).TheICD
HPdoesnotknowthecapacityof
yourcontroller.
ReservedStations:Itispossibletoassign“000”toadecoderoutputwiththeICDHP.Thisoutputwillnotbeused.
However,itmaybeprogrammedatalaterdate,toaddanewstationtoa
multistationdecoder.
Forexample,asixstationdecodercould
haveoutput#6(oranyother
outputs)settostation000.The000outputswouldnotbeoperational,but
couldbereservedforfutureadditions.Thenthenewstationnumbercould
beassignedtothereserved000outputwiththeICDHP.
Donotassignastation000unlessyouwish
toskipastation,orreserveone
forfutureexpansion.Stationnumber000cannotbeturnedonbya
controller!
StationsinRandomOrder:Itispossibletoassignanyvalidstationnumbersinanyorder.TheICDHPcanenterany
stationnumbersinamultistationdecoderin
anyorder.Thiscannotbedonefromthecontroller’sdecoderprogramming,
butisanaddedfeaturewithICDHP.
-PROGRAM A DECODE
R
--
Output 1: Sta-001
Output 2: Sta-032
Output 3: Sta-025
Output 4: Sta-081
Output 5: Sta-014
Output 6: Sta-000
Press 3 To Program
SampleICD600displaywithrandomstation
numbersandOutput6heldinreserve(000).