User's Manual

15
ProgramDecoderwillenterthestationaddressesandothersettingsofthedecoder.
MovethepointerwiththearrowbuttonsattheMainMenuscreento
ProgramDecoderandpressNext3.
TheICDHPwillcheckforadecoder.Ifsuccessful,itwilldisplaytheType,
PowerFactor,
andInrushinformationforthedecoderafterafewseconds.
Type:Pressthe+andbuttonstochangethedecodertype.Itispossibleto
changeastationdecodertoPump,toassignittooneoftheP/MV
(Pump/MasterValve)outputsforthecontroller.Itisbestto
useasingle
stationdecoderforaP/MVoutput.IfamultistationdecoderissettoType
Pump,theotheroutputscannolongerbeused,andwillbewasted.
IftheTypeshownis“Sensor”,theICDHPisreadingaSensorDecoderandthe
Typecannotbechanged.
PwrFactor:PowerFactor.Defaultsettingis2andthisistherecommended
setting.ThePowerFactorcanbeincreasedforcertainhighcurrent
requirements(suchasPumpStartRelays),butthiscandegradeperformance
forotherstationsontheline.Changeonlywhenrequired.
PROGRAM A DECODE
R
----------------------
Dec Type: 6-Station
Pwr Factor: 2
Inrush: 3
Press 3 To Continue
-PROGRAM A DECODE
R
--
Output 1: Sta-027
Output 2: Sta-000
Output 3: Sta-000
Output 4: Sta-000
Output 5: Sta-000
Output 6: Sta-000
Press 3 To Program