See page 2 ENGLISH Español Vea la página 19 Voir page 34 FRANÇAIS Models 30580, 30581, & 30582 Replacement Filter Information Models Main Filter 30580, 30581, 30582 30987 www.hunterfan.
Table of Contents Introduction ................................................................................................ 2 Safety Instructions . ................................................................................... 3 Description of Air Sterilization System How the Air Sterilizer Works................................................................. 4 Air Sterilizer Components.................................................................... 4 Controls and Indicators...................
SAFETY INSTRUCTIONS IMPORTANT! READ ALL INSTRUCTIONS BEFORE USING THIS Air Sterilizer. ! WARNING - RISK OF ELECTRIC SHOCK To reduce the risk of electric shock, do not per form any servicing other than that contained in these operating instructions unless you are qualified to do so. CAUTION This equipment should be inspected frequently and collected dir t removed from it regularly to prevent excessive accumulation that could result in flashover or risk of fire. 1.
Description of Air Sterilization System How the Air Sterilizer Works Dust & Irritants Pollen & Allergens Germs & Bacteria Dirty Air In Pet Hair & Dander Clean Air Out Pre-Filter Patented Main Filter Germicidal Technology Fig. 1 - Illustration of the Air Sterilization System Air Sterilizer Components Top Cover Main Filter Pre-Filter Base Unit Back Front Fig.
Description of Air Sterilization System Controls and Indicators Main Filter Reset Button Power Indicator Off Low Medium High Fan Speed Control Dial Fan Speed Control Dial (Top Cover Removed) Pre-Filter Reset Button Fault Indicator Fig.
Operation Initial Operation NOTE: The power cord has a three-prong grounded plug, and must be used with an electrical outlet that can accommodate the grounding pin. DO NOT use an adaptor if your power outlet can not accommodate the three-prong grounded plug. DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE GROUNDING PIN FROM THIS PLUG. 1. Remove the Air Sterilizer from its box and remove the clear plastic protective bag. Place the unit on a firm level floor. 2.
Air Sterilizer Maintenance Filter Life Counters When the Pre-Filter Life Counter exceeds 1400 hours, the Pre-Filter Indicator will flash amber as a reminder that you should clean the Pre-Filter. When the Main Filter Life Counter exceeds 8000 hours, the Main Filter Indicator will flash amber as a reminder that you should change the Main Filter. Main Filter Indicator (Amber, flashing) Pre-Filter Indicator (Amber, flashing) Fig.
Air Sterilizer Maintenance Cleaning the Pre-Filter and Changing the Main Filter (cont.) NoteS: • The Air Sterilizer must be unplugged during the cleaning process. • The Pre-Filter will fit into the unit ONLY when oriented correctly. If the Pre-Filter does not slide easily into the unit, do not force it. Simply turn the Pre-Filter around, and reinsert it into the unit. • The Air Sterilizer will not operate if the Pre-Filter is either out of the unit, or is not seated correctly in the unit.
Air Sterilizer Maintenance Cleaning the Pre-Filter and Changing the Main Filter (cont.) NoteS: • The Air Sterilizer must be unplugged during the cleaning process. • The Main Filter will fit into the unit ONLY when positioned correctly. The Main Filter has ridges that fit into grooves in the Base. • The Air Sterilizer will not operate if the Main Filter is either out of the unit, or is not seated correctly in the unit. To change the Main Filter and reset the Main Filter Life Counter: 1.
Air Sterilizer Maintenance Cleaning the Pre-Filter and Changing the Main Filter (cont.) 3. Reset the Main Filter Life Counter by pressing the Main Filter Reset Button. See Figure 9. Main Filter Reset Button Fan Speed Control Dial (Top Cover Removed) Fig. 9 - Resetting the Main Filter Life Counter NoteS: • Make certain the Pre-Filter, the Main Filter, and the Top Cover are installed correctly.
Air Sterilizer Maintenance Resetting the Air Sterilizer In addition to the Pre-Filter and Main Filter Indicators, the Air Sterilizer has a red LED Fault Indicator. See Figure 11. Fault Indicator Fig. 11 - Fault Indicator Should the Fault Indicator ever come on, reset the Air Sterilizer. 1. Turn off the Air Sterilizer. 2. Unplug the unit for 5 seconds. 3. Check the Pre-Filter and the Main Filter for excessive dirt accumulation. (Refer to Cleaning the Pre-Filter and Changing the Main Filter, pg. 7) 3.
Troubleshooting Problem Solutions 1. Unit does not operate. • Confirm that the unit is plugged in. • Check the installation of the Pre-Filter, the Main Filter, and the Top Cover. (See pgs. 8, 9, & 10.) 2. Unusual noise; popping, sizzling, etc. • Reset the Air Sterilizer. (See Resetting the Air Sterilizer, pg. 11.) • Check the installation of the Pre-Filter, the Main Filter, and the Top Cover. (See pgs. 8, 9, & 10.) 3. Pre-Filter and/or Main Filter indicator is on.
Warranty Technical Support If you have any additional questions or problems with your Hunter Air Sterilizer, please call 1-888-830-1326, or contact us over the Internet at www.hunterfan.com.
Warranty To obtain service, contact the Hunter Fan Company Service Department, 2500 Frisco Avenue, Memphis, Tennessee 38114, 1-888-830-1326. You will be responsible for insurance and freight or other transportation to our factory service center. We will return the Air Sterilizer freight prepaid. The Air Sterilizer should be properly packaged to avoid damage in transit since we will not be responsible for any such damage. Proof of purchase is required when requesting warranty service.