Specification Sheet
SPECIFICATIONS (Refer to 6187-T for substructure construction requirements)
RX10JFT
& RX10FT-PS
Flush Mount Lift Rack
Form 6494-T, 06-15
Supersedes Form 6494-T, 12-12a
Copyright © 2015, Hunter Engineering Company
Dimensions shown are for nished pit. Tile thickness (if applicable) must be considered before pouring pit.
*Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet
(1829 mm) at the approach ramp end and 18 feet (5486 mm) at the turnplate end. Additional threshold and perhaps
hydraulic hoses will be required (refer to Installation Instruction for details).
!
WARNING
STAY BEHIND
YELLOW LINE
WHEN THE
LIFT MOVES.
128-978-2
DECAL 128-978-2
PLACED ON EACH
PERIMETER ANGLE
(4 PLACES)
AND EACH SIDE OF
LIFT (2 PLACES)
!
WARNING
!
WARNIN G
!
WARNING
!
WARNING
APPROX. 2"
(51 mm)
TYPICAL
24 1/4"
(616 mm)
DRAIN
LOCATED
IN
CENTER
OF PIT
ANGLE AROUND PIT
PERIMETER
PAINTED SAFETY
YELLOW
(NOT SUPPLIED BY
HUNTER)
SLOPE
PIT
FLOOR
TOWARD
DRAIN
(1/2")
CONSOLE CONDUIT
DETAIL
RAMPS
147-141-1-PPP
EXTENDER
PLATES
51-2464-1-PPP
AND
RAMPS
147-141-1-PPP
215 3/8"
(5471 mm)
92 1/2"
(2350 mm)
34 3/4"
(883 mm)
OPTIONAL CONSOLE
LOCATION
60 1/4"
(1530 mm)
6" MIN.*
152 mm()
16"
(406
mm)
22"
(559 mm)
OPTIONAL 1 1/2" DIA. CONDUIT
FOR COMMUNICATION CABLE
TO ALIGNMENT CONSOLE
HAWKEYE SERIES SENSORS
AND PRONTO SYSTEMS HAVE
SPACE REQUIREMENTS IN
FRONT OF LIFT THAT MUST BE
MET, REFER TO APPROPRIATE
SITE REQUIREMENTS.
ENTIRE PIT
(BOTTOM AND WALLS)
MUST BE HARD
TROWEL FINISH
*
LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TO
ACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO () OR
GREATER.
39" 991 mm
** SITES WITH D.R.W. TRUCK
TRAFFIC SHOULD USE 20" MIN.
CONSOLE TO PIT DISTANCE.
**
15" TO 41"
(381 TO 1041 mm)
45
6" MIN.
RADIUS
CONDUIT
EXIT FLUSH
WITH
PIT FLOOR
ROUTE 4" MIN DIAMETER
CONDUIT OR EQUIVALENT
CLOSED CHANNEL FROM
PIT FLOOR TO BASE OF
CONSOLE
BAY DOOR
BAY DOOR
VEHICLE APPROACH