User's Manual
NOT FOR DISTRIBUTION
PowerView
™
AC motor
Quick Start Guide
— Release Candidate —
Release Candidate ©2016 Hunter Douglas. All rights reserved. Page
8 of 11
M50PV1234
12
34
1.1
M50PV1530
15
30
1.1
M50PV2017
20
17
0.8
M50PV2521
25
21
0.8
M50PV3017
30
17
1.2
M50PV3521
35
21
1.2
M50PV4016
40
16
1.5
M50PV4017
40
17
1.8
M50PV5014
50
14
1.5
Never exceed the lift capacity from the above table.
A Motor that is cool may run for up to 4 minutes continuously before thermal overload. If the motor is
run for more than up to 4 minutes continuously, the motor may overheat. A motor thermal will act
exactly like a stall. Thermal reset occurs after the motor has cooled sufficiently, this usually takes 10
to 15 minutes depending on ambient temperature and ventilation.
C. Safety
WARNING: Prior to installation inspect all parts for damage or missing components.
WARNING: To Reduce the Risk Of Fire, Electric Shock, Or Injury To Persons, Installation Work And
Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And
Standards.
WARNING: Never install this product with power connected. DISCONNECT FROM POWER
SUPPLY before installing or adding accessories to this device.
WARNING: Important safety instructions. It is important for the safety of persons to follow these
instructions. Save these instructions. Frequently examine the installation for imbalance and signs of
wear or damage to cables and springs. Do not use if repair or adjustment is necessary.
Do not allow children to play with fixed controls. Keep remote controls away from children. Children
should be supervised to ensure that they do not play with the appliance.
The supplied UL rated grounding power cord on models M40PV330 / M40PV334 / M40PV430 /
M40PV620 / M40PV624 / M40PV915 if lost or broken, shall be only replaced with an identical power
cord. A Replacement power cord is available from distributor or manufacturer.
The power cord must be properly plugged into the electrical outlet and the proper motor model.
Loose attachment can cause arcing and can result in failure. Any improper use or misuse can result
in electrical shock causing injury to the person or persons.