Operation Manual
12
Continuous Running (CR model with solenoid valves)
The gauge of the cables should be chosen depending on the power of the pack driven, the voltage,
and the length of these connections. Use the following guidelines:
Motor Copper Area AWG specs
Up to 100Watts 2.5mm2 13 AWG
From 100 to 200Watts 4.0mm2 11 AWG
From 200 to 350Watts 6.0mm2 9 AWG
Solenoids and/or Clutch Copper Area AWG specs
Any 1.5mm2 15 AWG
Constant Running
Pump
SCP110
TB11SOLENOIDS
CR. MOTORMOTOR
MOTOR
MOTOR
MOTOR +
MOTOR –
LEFT
L
EFT
RIGHT
RIGHT
LEFT +
LEFT –
RIGHT +
RIGHT –
Wiring MOTOR: CR. MOTOR faston connectors.
SOLENOIDS: TB11 connector.
Software Settings
(SC110 Installation Mode)
POWER STEERING TYPE function should be set to SOL.