Signal Connectors / Assembly Instructions
Panel Connector with Strain Relief
- Push dome nut (1), clamping insert (2) and adapter (3) over the cable
- Strip the cable jacket back 20 mm (3/4“)
- Strip the wire ends 4 mm (5/32“) max.
- Solder or crimp the contacts
- Push the contacts into the insert (5)
- Fold the spacer (4) around the wires and push it onto the insert (5)
- Push the insert (5) with the spacer (4) into the housing.
Pay attention to the desired coding (coding groove, coding key)!
- Push adapter (3) onto the panel connector (6) and screw together
- Push the clamping insert (2) into the adapter (3) and tighten the dome nut (1)
- Mount panel connector to panel
Panel Connector with Strain Relief
coding groove
detail A
detail B
- Slide dome nut (1), clamping insert (2), adaptor (3) and EMI ring (4)
over the cable
- Strip the cable jacket back 20 mm (3/4“). Shorten the braided shield
to 10 mm (3/8“)
- Fold the braided shield over the cable
- Push the EMI ring (4) over the wires onto the braided shield.
Caution: Don’t push the EMI ring behind the braided shield (detail A)!
- Strip the wire ends 4 mm (5/32“) max.
- Solder or crimp the contacts
- Push the contacts into the insert (6)
- Fold spacer (5) around the wires and push it on the insert (6)
- Push the EMI ring (4) on to the spacer (5)
- Fold the braided shield over the EMI ring (detail B)
- Push insert (6) and spacer (5) assembly into the coupling body (7).
Pay attention to the desired coding (coding groove, coding key)!
- Push adapter (3) on to the coupling body (7) and screw it together
- Push the clamping insert (2) into adapter (3), tighten the dome nut (1)
to grip and seal the cable